首页> 美国卫生研究院文献>PLoS Clinical Trials >Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis
【2h】

Test-retest reliability and minimal detectable change scores for the short physical performance battery, one-legged standing test and timed up and go test in patients undergoing hemodialysis

机译:血液透析患者的短物理性能电池,单腿站立测试和定时测试的重新测试可靠性和最小可检测变化分数

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Functional tests are commonly used for chronic kidney disease (CKD) patients undergoing hemodialysis (HD). However, the relative and absolute reliability of such physical performance-outcome assessments must first be determined in specific patient cohorts. The aims of this study were to assess the relative and the absolute reliability of the Short Physical Performance Battery (SPPB), One-Legged Stance Test (OLST), and Timed Up and Go (TUG) test, as well as the minimal detectable change (MDC) scores for these tests in CKD patients receiving HD. Seventy-one end-stage CKD patients receiving HD therapy, aged between 21 and 90 years, participated in the study. The patients completed two testing sessions one to two weeks apart and performed by the same examiner, comprising the following tests: the SPPB (n = 65), OLST (n = 62), and TUG test (n = 66). High intraclass correlation coefficients (≥0.90) were found for all the tests, suggesting that their relative reliability is excellent. The MDC scores for the 90% confidence intervals were as follows: 1.7 points for the SPPB, 11.3 seconds for the OLST, and 2.9 seconds for the TUG test. The reliability of the SPPB, OLST, and TUG test for this sample were all considered to be acceptable. The MDC data generated by these tests can be used to monitor meaningful changes in the functional capacity of the daily living-related activity of CKD patients on HD.
机译:功能测试通常用于接受血液透析(HD)的慢性肾脏疾病(CKD)患者。但是,必须首先在特定的患者队列中确定此类身体绩效结果评估的相对和绝对可靠性。这项研究的目的是评估短物理性能电池(SPPB),单腿姿态测试(OLST)和定时起跑(TUG)测试的相对和绝对可靠性,以及最小的可检测变化(MDC)在接受HD的CKD患者中进行这些测试的分数。接受HD治疗的71位终末期CKD患者年龄在21至90岁之间,参加了该研究。患者每隔一到两周完成两次测试,由同一位检查员进行,包括以下测试:SPPB(n = 65),OLST(n = 62)和TUG测试(n = 66)。在所有测试中都发现了较高的组内相关系数(≥0.90),这表明它们的相对可靠性非常好。 90%置信区间的MDC得分如下:SPPB为1.7分,OLST为11.3秒,TUG测试为2.9秒。该样品的SPPB,OLST和TUG测试的可靠性都被认为是可以接受的。这些测试生成的MDC数据可用于监视CKD患者HD的日常生活相关活动功能能力的有意义变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号