The aim of this study was to evaluate the corneal posterior curvature changes after phacoemulsification cataract surgery, with intraocular lens implantation, with a temporal limbal self-sealing 2.75 millimeters (mm) corneal incision, using a Placido-dual rotating Scheimpflug device. In this prospective intervention study, corneal posterior curvature changes were evaluated in fifty-six patients (56 eyes). All patients underwent corneal tomography using the Galilei G2 (Ziemer Ophthalmic System AG, Port, Switzerland) preoperatively (PRE) and with two weeks (RP15), one month (RP30), and three months (RP90) after phacoemulsification cataract surgery with a temporal limbal self-sealing 2.75 mm incision. Tomographic parameters analyzed in the posterior cornea were the steep curvature (K2), flat curvature (K1), mean curvature (average K), and posterior corneal astigmatism. We did not observe any statistically significant change in the K2, K1, average K, and posterior corneal astigmatism in any postoperative follow-up measurements (RP15, RP30, RP90), showing that the postoperative values tend to be the same as the preoperative ones when measured with the Galilei G2 tomography. In conclusion, the 2.75 mm temporal limbal self-sealing corneal incision in phacoemulsification cataract surgery does not induce significant changes in the posterior corneal curvature parameters of K2, K1, average K, and astigmatism.
机译:这项研究的目的是通过使用Placido-Dual旋转Scheimpflug装置评估超声乳化白内障手术,人工晶状体植入,临时角膜缘自密封2.75毫米(mm)角膜切口后的角膜后曲率变化。在这项前瞻性干预研究中,对56例患者(56眼)的角膜后曲率变化进行了评估。所有患者均在术前(PRE),使用超声乳化白内障白内障手术(临时),分别在两周(RP15),一个月(RP30)和三个月(RP90)时使用Galilei G2(瑞士波特,Ziemer眼科系统AG)进行了角膜断层扫描。角膜缘自密封2.75毫米切口。在角膜后角中分析的层析成像参数为陡曲率(K2),平曲率(K1),平均曲率(平均K)和后角膜散光。在任何术后随访测量(RP15,RP30,RP90)中,我们均未观察到K2,K1,平均K和角膜后散光有任何统计学上的显着变化,表明术后值倾向于与术前值相同。用Galilei G2层析成像进行测量时。总之,在超声乳化白内障手术中,2.75 mm颞侧角膜缘自密封角膜切口不会引起K2,K1,平均K和散光后角膜曲率参数的显着变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号