首页> 美国卫生研究院文献>Malaysian Orthopaedic Journal >The Use of Dual Reconstruction Plates for Failed Fixation of Patellar Fracture after Total Knee Replacement: A Case Report
【2h】

The Use of Dual Reconstruction Plates for Failed Fixation of Patellar Fracture after Total Knee Replacement: A Case Report

机译:全膝关节置换术后of骨骨折双固定重建失败的应用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Patellar fracture after total knee replacement (TKR) is one of the challenging problems in periprosthetic fracture. Open reduction with internal fixation (ORIF), as tension band wiring (TBW), usually required in cases with extensor mechanism disruption. However, many studies reported a high failure rate after using this technique. In this report, we presented an interesting case of periprosthetic patellar fracture after TKR with TBW failure that was successfully treated with double non-locking reconstruction plates fixation and TBW augmentation.
机译:全膝关节置换(TKR)后的骨骨折是假体周围骨折的难题之一。伸肌机制中断的情况下通常需要使用内部固定(ORIF)作为张力带接线(TBW)进行切开复位。但是,许多研究报告使用此技术后故障率很高。在本报告中,我们介绍了TKR合并TBW失败后假体pa骨骨折的有趣情况,该病例成功通过双重非锁定重建钢板固定和TBW增强治疗。