首页> 美国卫生研究院文献>Lippincott Williams Wilkins Open Access >Primary Intravenous Set Consumption Across 3 Branded Infusion Pumps
【2h】

Primary Intravenous Set Consumption Across 3 Branded Infusion Pumps

机译:3个品牌输液泵的主要静脉设定消耗量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

This retrospective study of 6426 hip replacement, coronary artery bypass graft, and colectomy surgeries across 23 US hospitals found that intravenous (IV) set designs that can be interchanged for use both in gravity-fed and automated pump delivery systems are replaced less frequently than IV sets designed for use primarily by one delivery method. Semistructured interviews with nurses highlighted the impact of set design on nursing workflow when moving between gravity-fed and pump-based administration. Use of interchangeable, single-design IV sets across gravity and automated infusions minimizes disruptions to closed systems, may reduce nurses being distracted from patients' clinical needs when replacing sets, and may yield supply cost savings.
机译:这项对美国23所医院的6426例髋关节置换术,冠状动脉搭桥术和结肠切除术进行的回顾性研究发现,可以互换用于静脉注射和自动泵输送系统的静脉(IV)套件设计比IV更换的频率更低主要设计用于一种交付方式的套件。对护士进行的半结构化访谈着重指出了在重力喂食和基于泵的管理之间切换时,布景设计对护理工作流程的影响。跨重力使用可互换,单一设计的静脉输液器和自动输液可最大程度地减少对封闭系统的干扰,可以减少护士在更换输液器时对患者临床需求的分心,并可以节省供应成本。