首页> 美国卫生研究院文献>Frontiers in Neuroscience >The Effects of Stimulator, Waveform, and Current Direction on Intracortical Inhibition and Facilitation: A TMS Comparison Study
【2h】

The Effects of Stimulator, Waveform, and Current Direction on Intracortical Inhibition and Facilitation: A TMS Comparison Study

机译:刺激物,波形和电流方向对皮层内抑制和促进的影响:TMS比较研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: Cortical function is dependent on the balance between excitatory and inhibitory influences. In the human motor cortex, surrogates of these interactions can be measured in vivo, non-invasively with double-pulse transcranial magnetic stimulation (TMS). To compare results from data acquired with different available setups and bring data together, it is inevitable to determine whether different TMS setups lead to comparable or differential results.Objective: We assessed and compared short intracortical inhibition (SICI) and intracortical facilitation (ICF) testing four different experimental conditions.Methods: SICI and ICF were studied with different stimulators (Magstim BiStim2 or MagVenture MagPro X100), waveforms (monophasic or biphasic), current directions (anterior-posterior or posterior-anterior) at interstimulus intervals (ISIs) of 1, 3, 10, 15 ms.Results: We were not able to detect differences for SICI and ICF, when comparing the tested conditions, except for 3 ms SICI in which the anterior-posterior current direction led to stronger modulation. Correlation analysis suggested comparability for 3 ms SICI for the Magstim monophasic posterior-anterior condition with both tested MagVenture conditions.Conclusions: 3 ms SICI data sets obtained with two different, commonly used stimulators (Magstim BiStim2 or MagVenture MagPro X100) with conventionally used stimulation parameters are largely comparable. This may allow the combination of data sets in an open science view.
机译:背景:皮质功能取决于兴奋性和抑制性影响之间的平衡。在人类运动皮层中,可以使用双脉冲经颅磁刺激(TMS)在体内无创地测量这些相互作用的替代物。为了比较使用不同可用设置获取的数据的结果并将数据汇总在一起,不可避免地要确定不同的TMS设置是导致可比较的结果还是差异化的结果。目的:我们评估并比较了短暂皮质内抑制(SICI)皮质内促进(ICF)测试四种不同的实验条件。方法:使用不同的刺激器(Magstim BiStim 2 或MagVenture MagPro X100),波形(单相或正交)研究SICI和ICF。刺激间隔(ISI)为1、3、10、15毫秒的双相电流,当前方向(前后或前后)。结果:我们无法检测出SICI和ICF的差异,当比较测试条件时,除了3 ms SICI(其中前后电流方向导致更强的调制)。相关分析表明,两种测试的MagVenture条件在Magstim单相前后状态下的3 ms SICI具有可比性。结论:使用两种不同的常用刺激器(Magstim BiStim 2 或具有常规使用的刺激参数的MagVenture MagPro X100)在很大程度上具有可比性。这可以允许在开放式科学视图中组合数据集。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号