首页> 美国卫生研究院文献>International Journal of Pharmaceutics: X >Size-induced segregation during die filling
【2h】

Size-induced segregation during die filling

机译:模具填充过程中尺寸引起的偏析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

class="kwd-title">Keywords: Segregation, Particle size, Die filling, Tabletting, Powder flow class="head no_bottom_margin" id="ab010title">AbstractThe present study investigated particle size-induced segregation during die filling of binary pharmaceutical blends, consisting of fine and coarse particles in various fractions. Coarse fraction was made of milled and sieved acetylsalicylic acid, whereas the fine fraction was mannitol. The die filling process was carried out in gravity filling and suction filling. The segregation was assessed through determination of the coarse component concentration using UV–Visible spectrophotometry. The obtained values of concentration, determined for ten units of identical volume inside the die, were used to calculate the segregation index (SI), which was an indicator of uniformity of the powder blend deposited into the die. It was found that high segregation tendency was generally observed during gravity filling at a low velocity, due to the effect of air drag, and during gravity filling at a high velocity, as it was carried out through three consecutive filling steps. The lowest segregation tendency was generally observed during suction filling at a low velocity. The horizontal segregation was mostly observed in the top layers of the die, due to mainly two mechanisms: coarse particles cascading down the heap formed by the powder in the final steps of die filling, which produces higher coarse concentration at the near side of the die, observed at low coarse concentration; or coarse particle cascading down the top surface of the flowing powder stream into the die, which increases the coarse concentration at the far end of the die.
机译:<!-fig ft0-> <!-fig @ position =“ anchor” mode =文章f4-> <!-fig mode =“ anchred” f5-> <!-fig / graphic | fig / alternatives / graphic mode =“ anchored” m1-> class =“ kwd-title”>关键字:偏析,粒度,模具填充,压片,粉末流量 class =“ head no_bottom_margin” id =“ ab010title”>摘要本研究调查了二元药物混合物压模填充过程中由粒度引起的偏析,该混合物由不同比例的细颗粒和粗颗粒组成。粗级分由研磨和过筛的乙酰水杨酸制成,而细级分是甘露醇。模具填充过程在重力填充和抽吸填充中进行。通过使用紫外可见分光光度法测定粗组分的浓度来评估偏析。对于模具内十个相同体积的单位确定的浓度获得的值,用于计算偏析指数(SI),该指数是沉积到模具中的粉末混合物均匀性的指标。已经发现,由于空气阻力的影响,在低速重力填充期间和在高速重力填充期间通常观察到高的偏析趋势,这是通过三个连续的填充步骤进行的。通常在低速抽吸填充过程中观察到最低的偏析趋势。水平隔离主要在模具的顶层观察到,主要是由于以下两种机制:在模具填充的最后步骤中,粗颗粒从粉末形成的堆垛中层叠下来,在模具的近侧产生较高的粗浓度,在低粗浓度下观察到;或向下流动的粉末流的顶部表面向下流进模具的粗颗粒,这会增加模具远端的粗浓度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号