In present study, a DLLME-HPLC-UV method was developed and validated for the extraction, pre–concentration, and subsequently quantification of vitamin D3 (Vit D3) in milk and yogurt samples. In order to be able to extract Vit D3 from studied samples efficiently, the DLLME procedure was optimized with respect to the parameters affecting the extraction efficacy, where acetonitrile (2 mL as disperser solvent) resulting from the protein precipitation procedure was mixed with 80 µL carbon tetrachloride (as an extraction solvent) respectively. The extracted samples were quantitatively analyzed with a HPLC technique using a C8 column (250 mm × 4.6 mm, 5 μm) at room temperature (25 °C), mobile phase of acetonitrile/methanol (90:10% v/v) in isocratic elution mode at a flow rate of 1.2 mL/min and UV detection at 265 nm. The method validation results revealed that the method was linear in the concentration range of 2 to 60 ng/mL (r = 0.9997) with a LOD of 0.9 ng/mL and LLOQ of 2 ng/mL; the method was accurate (-2.1% ≤ RE% ≤ +0.6%) and precise (1.2% ≤RSD% ≤ 11.3%) and its recovery was in the range of 86.6 to 113.3%. The obtained results indicated that the method could be utilized as an easy to use technique for the monitoring Vit D3 in dairy products, especially milk and yogurt samples.
机译:在本研究中,开发了一种DLLME-HPLC-UV方法,并验证了其在牛奶和酸奶样品中维生素D3(Vit D3)的提取,预浓缩和随后定量的有效性。为了能够有效地从研究样品中提取Vit D3,针对影响提取效果的参数对DLLME方法进行了优化,其中将蛋白质沉淀过程中产生的乙腈(2 mL作为分散剂)与80 µL碳混合。四氯化物(作为萃取溶剂)。提取的样品通过HPLC技术在室温(25°C)下使用C8色谱柱(250 mm×4.6 mm,5μm)进行定量分析,乙腈/甲醇(90:10%v / v)流动相洗脱模式,流速为1.2 mL / min,紫外检测波长为265 nm。方法验证结果表明,该方法在2至60 ng / mL的浓度范围内是线性的(r = 0.9997),LOD为0.9 ng / mL,LLOQ为2 ng / mL。该方法是准确的(-2.1%≤RE%≤+ 0.6%)和精确的(1.2%≤RSD%≤11.3%),其回收率在86.6至113.3%的范围内。获得的结果表明,该方法可作为一种易于使用的技术来监测乳制品,尤其是牛奶和酸奶样品中的Vit D3。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号