首页> 美国卫生研究院文献>Iranian Journal of Pharmaceutical Research : IJPR >Development of a Simple RP-HPLC-UV Method for Determination of Azithromycin in Bulk and Pharmaceutical Dosage forms as an Alternative to the USP Method
【2h】

Development of a Simple RP-HPLC-UV Method for Determination of Azithromycin in Bulk and Pharmaceutical Dosage forms as an Alternative to the USP Method

机译:建立简单的RP-HPLC-UV方法测定大剂量和药物剂量形式的阿奇霉素以替代USP方法

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The present study was designed to develop a simple, validated liquid chromatographic method for the analysis of azithromycin in bulk and pharmaceutical dosage forms using ultraviolet detector. The best stationary phase was determined as C18 column, 5 μm, 250 mm × 4.6 mm. Mobile phase was optimized to obtain a fast and selective separation of the drug. Flow rate was 1.5 mL/min, Wavelength was set at 210 nm and the volume of each injection was 500 μL. An isocratic methanol/buffer mobile phase at the ratio of 90:10 v/v gave the best separation and resolution. The proposed method was accurate, precise, sensitive, and linear over a wide range of concentration of azithromycin. The developed method has the advantage of using UV detector compared to the USP method in which electrochemical detector has been used. The validated method was successfully applied to the determination of azithromycin in bulk and pharmaceutical dosage forms.
机译:本研究旨在开发一种简单有效的液相色谱方法,用于使用紫外线检测器分析散装和药物剂型的阿奇霉素。确定最佳固定相为C18色谱柱,5μm,250 mm×4.6 mm。优化了流动相以获得快速,选择性的药物分离。流速为1.5 mL / min,波长设置为210 nm,每次进样量为500μL。等度甲醇/缓冲液流动相的比例为90:10 v / v,可实现最佳分离和分离度。所提出的方法在广泛的阿奇霉素浓度范围内是准确,精确,灵敏和线性的。与使用电化学检测器的USP方法相比,该方法具有使用UV检测器的优势。验证的方法已成功应用于散装和药物剂型中阿奇霉素的测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号