The aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:YAG laser (250 mJ/4Hz); and Group III- CVDentus ultrasouns tips. All devices were used with water cooling. Class V cavities were prepared to a depth of 3.5 mm, measured with a periodontal probe. A type T thermocouple was placed inside the pulp chamber to determine the temperature increase (°C), which was recorded by a data acquisition system ADS 2000 IP (Lynx Technology) linked to a notebook computer. Data were analyzed statistically by oneway ANOVA and Tukey's test (p=0.05). The mean temperature rises were: 1.10°C (±0.56) for Group I, 0.84°C (±0.55) for Group II, and 3.00°C (± 1.34) for Group III. There were no statistically significant differences (p>0.05) between Groups I and II, but both of them differed significantly from Group III (p<0.05). In conclusion, the use of Er:YAG laser and high-speed handpiece for cavity preparation resulted in similar temperature increase. Although ultrasound tips generated significantly higher intrapulpal temperature increase, it remained below the critical value of 5.5°C and may be considered safe for use.
机译:这项研究的目的是比较在准备腔时由高速手机,Er:YAG激光和CVDentus超声探头产生的肺内温度升高。颊侧牙釉质/牙本质厚度为4 mm的30头牛下颌切牙的根部被切断,并分为以下几组(n = 10):I组-高速手机; II组-非接触式Er:YAG激光(250 mJ / 4Hz);和III-CVDentus超音波提示。所有设备均使用水冷。用牙周探针测量,准备V级腔至3.5 mm的深度。将T型热电偶放置在纸浆腔室内以确定温度升高(°C),该温度升高由与笔记本计算机相连的数据采集系统ADS 2000 IP(Lynx Technology)记录。数据通过单因素方差分析和Tukey检验进行统计分析(p = 0.05)。平均温度升高为:第一组为1.10°C(±0.56),第二组为0.84°C(±0.55),第三组为3.00°C(±1.34)。第一组和第二组之间没有统计学上的显着差异(p> 0.05),但是它们与第三组之间都存在显着差异(p <0.05)。总之,使用Er:YAG激光和高速机头进行腔体制备会导致类似的温度升高。尽管超声头产生的肺内温度明显升高,但仍低于5.5°C的临界值,可以认为使用安全。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号