The purpose of this study was to evaluate in vivo the biocompatibility of Endométhasone, Pulp Canal Sealer EWT and AH-Plus root canal sealers after implantation in rat connective tissue. Twenty-four Wistar-Furth rats were used. Polyethylene tubes were filled with the sealers and implanted into specific dorsal subdermal tissue sites of the rats. Implants were removed after 3, 7 and 30 days, fixed and processed for glycol methacrylate-embedding technique to be examined microscopically. On the 3rd day, there was a mild inflammatory reaction to Pulp Canal Sealer EWT implants, but a severe response to the other sealers with presence of acute inflammatory cells. On the 7th day, tissue organization was more evident with attenuation of the inflammatory reaction, especially for the AH-Plus implants. On the 30th day, connective tissue with few inflammatory cells was observed in contact with all sealer implants. In this time interval, the tissue in contact with Pulp Canal Sealer EWT implants was more organized, while the tissue close to Endométhasone and AH-Plus implants showed a mild persistent inflammatory reaction and had similar results to each other. In conclusion, the sealers had a similar pattern of irritation, which was more severe in the beginning and milder with time, in such a way that all sealers showed a persistent mild reaction. Pulp Canal Sealer EWT yielded better tissue organization than Endométhasone and AH-Plus, which, in turn, showed similar results to each other.
机译:这项研究的目的是在植入大鼠结缔组织后评估Endométhasone,纸浆管封闭剂EWT和AH-Plus根管封闭剂的体内生物相容性。使用了24只Wistar-Furth大鼠。用密封剂填充聚乙烯管,并将其植入大鼠的特定背侧皮下组织部位。 3、7和30天后取出植入物,固定并进行甲基丙烯酸乙二醇酯包埋技术的处理,以进行显微镜检查。在第3天,对髓腔封闭器EWT植入物发生了轻度的炎症反应,但是在存在急性炎症细胞的情况下,对其他封闭物的反应却很严重。在第7天,随着炎症反应的减弱,组织组织更加明显,尤其是对于AH-Plus植入物。在第30天,与所有封闭剂植入物接触时,观察到具有少量炎症细胞的结缔组织。在此时间间隔内,与牙髓封闭器EWT植入物接触的组织更加组织,而与内膜颂酮和AH-Plus植入物接近的组织表现出轻度的持续性炎症反应,并且彼此具有相似的结果。总之,密封剂具有类似的刺激性模式,这种刺激在开始时就更严重,并且随着时间的流逝更温和,从而所有密封剂都表现出持续的轻度反应。纸浆管封闭剂EWT的组织结构优于Endométhasone和AH-Plus,后者的结果相似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号