首页> 美国卫生研究院文献>Journal of Biomedical Optics >Reliability and reproducibility of macular segmentation using a custom-built optical coherence tomography retinal image analysis software
【2h】

Reliability and reproducibility of macular segmentation using a custom-built optical coherence tomography retinal image analysis software

机译:使用定制的光学相干断层扫描视网膜图像分析软件进行黄斑分割的可靠性和可重复性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We determine the reliability and reproducibility of retinal thickness measurements with a custom-built OCT retinal image analysis software (OCTRIMA). Ten eyes of five healthy subjects undergo repeated standard macular thickness map scan sessions by two experienced examiners using a Stratus OCT device. Automatic∕semi automatic thickness quantification of the macula and intraretinal layers is performed using OCTRIMA software. Intraobserver, interobserver, and intervisit repeatability and reproducibility coefficients, and intraclass correlation coefficients (ICCs) per scan are calculated. Intraobserver, interobserver, and intervisit variability combined account for less than 5% of total variability for the total retinal thickness measurements and less than 7% for the intraretinal layers except the outer segment∕ retinal pigment epithelium (RPE) junction. There is no significant difference between scans acquired by different observers or during different visits. The ICCs obtained for the intraobserver and intervisit variability tests are greater than 0.75 for the total retina and all intraretinal layers, except the inner nuclear layer intraobserver and interobserver test and the outer plexiform layer, intraobserver, interobserver, and intervisit test. Our results indicate that thickness measurements for the total retina and all intraretinal layers (except the outer segment∕RPE junction) performed using OCTRIMA are highly repeatable and reproducible.
机译:我们使用定制的OCT视网膜图像分析软件(OCTRIMA)确定视网膜厚度测量的可靠性和可重复性。两名健康的检查员使用Stratus OCT设备,对五名健康受试者的十只眼睛进行了重复的标准黄斑厚度图扫描会议。使用OCTRIMA软件对黄斑和视网膜内层进行自动半自动厚度定量。计算每次扫描的观察者内,观察者间和观察间的重复性和再现性系数以及组内相关系数(ICC)。观察者间,观察者间和观察间的变异性合计占总视网膜厚度测量值的总变异度的不到5%,而视网膜内层(除了外部节段的视网膜色素上皮(RPE)结以外)的总变异度不到7%。在不同观察者或不同访问期间获得的扫描之间没有显着差异。对于观察者内部和观察者间变异性测试,对于总视网膜和所有视网膜内层,除内部核层观察者和观察者间测试以及外部丛状层,观察者内部,观察者间和观察者间测试外,获得的ICC均大于0.75。我们的结果表明,使用OCTRIMA进行的整个视网膜和所有视网膜内层(除外层∕ RPE交界处)的厚度测量是高度可重复和可重复的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号