>r10-2In confocal microscopy high fluorescence detection sensitivity translates into lower excitation intensity and less perturbation when imaging living specimens. While many factors enter into deciding on which spectral confocal to purchase, sensitivity is one that can be quantified and therefore objectively compared.With non-filter based spectral confocal microscopes becoming common, a method based on photon shot noise as a function of excitation intensity and a given spectral collection bandwidth is presented as straightforward means of sensitivity comparison. We recently carried out this sensitivity test on spectral confocal systems from all of the major confocal vendors and in this talk will present the method and the measurement results.
机译:> r10-2 在共聚焦显微镜中,对活体标本成像时,高荧光检测灵敏度可转化为较低的激发强度和较小的干扰。尽管有许多因素决定购买哪种光谱共焦,但灵敏度是可以量化的,因此可以进行客观比较。随着非滤光片光谱共焦显微镜的普及,一种基于光子散粒噪声作为激发强度和给出给定的频谱收集带宽是灵敏度比较的直接方法。我们最近在所有主要共焦供应商的光谱共焦系统上进行了此灵敏度测试,在本次演讲中将介绍该方法和测量结果。