首页> 美国卫生研究院文献>Journal of Bone and Joint Infection >Meta-analysis of sonicate fluid in blood culture bottles for diagnosing periprosthetic joint infection
【2h】

Meta-analysis of sonicate fluid in blood culture bottles for diagnosing periprosthetic joint infection

机译:血培养瓶中超声液的Meta分析用于假体周围关节感染的诊断

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Introduction: Periprosthetic joint infection (PJI) is the most serious complication after arthroplasty, and the diagnosis of PJI is still challenging with modern medical technology. To improve the diagnostic rate, combined diagnostic methods are gradually beginning to be used to diagnose PJI. Sonication is one accurate way to diagnose PJI, but there is minimal research regarding the diagnostic value of sonicate fluid (SF) in blood culture bottles (BCB). Therefore, we evaluated this combined diagnostic method by meta-analysis.>Methods: We searched English publications in electronic databases regarding the use of sonicate fluid in blood culture bottles (SF-BCB) for diagnosing PJI, screened the literature according to inclusion criteria, assessed the quality of the selected literature, and collected information regarding SF-BCB.>Results: This meta-analysis includes 4 studies that evaluated SF-BCB for the diagnosis of PJI. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratio (DOR) are 0.85 (95% Confidence interval [CI], 0.77 to 0.91), 0.86 (CI, 0.81 to 0.91), 5.34 (CI, 3.13 to 9.11), 0.16 (CI, 0.06 to 0.48) and 39.01 (CI, 9.04 to 168.35), respectively. The area under the curve (AUC) of the summary receiver operating characteristic (SROC) is 0.9186 (standard error, 0.0205).>Conclusion: SF-BCB has great value for the microbiological diagnosis of PJ, especially for patients with prior antibiotic treatment.
机译:>简介:假肢周围感染(PJI)是关节置换术后最严重的并发症,现代医学技术对PJI的诊断仍具有挑战性。为了提高诊断率,组合诊断方法逐渐开始用于诊断PJI。超声处理是诊断PJI的一种准确方法,但是关于血液培养瓶(BCB)中的超声液(SF)的诊断价值的研究很少。因此,我们通过荟萃分析评估了这种联合诊断方法。>方法:我们在电子数据库中搜索了有关在血培养瓶中使用超声液诊断PFJ的英文出版物,并筛选了>结果:这项荟萃分析包括4项评估SF-BCB诊断PJI的研究。合并的敏感性,特异性,阳性似然比(PLR),阴性似然比(NLR)和诊断比值比(DOR)为0.85(95%置信区间[CI],0.77至0.91),0.86(CI,0.81至0.91) ,5.34(CI,3.13至9.11),0.16(CI,0.06至0.48)和39.01(CI,9.04至168.35)。摘要接收器工作特性(SROC)的曲线下面积(AUC)为0.9186(标准误差,0.0205)。>结论: SF-BCB对于PJ的微生物诊断具有重要价值,特别是对于事先接受过抗生素治疗的患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号