Laboratory Evaluation of Low-Cost Optical Particle Counters for Environmental and Occupational Exposures

机译:用于环境和职业暴露的低成本光学粒子计数器的实验室评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Low-cost optical particle counters effectively measure particulate matter (PM) mass concentrations once calibrated. Sensor calibration can be established by deriving a linear regression model by performing side-by-side measurements with a reference instrument. However, calibration differences between environmental and occupational settings have not been demonstrated. This study evaluated four commercially available, low-cost PM sensors (OPC-N3, SPS30, AirBeam2, and PMS A003) in both settings. The mass concentrations of three aerosols (salt, Arizona road dust, and Poly-alpha-olefin-4 oil) were measured and compared with a reference instrument. OPC-N3 and SPS30 were highly correlated (r = 0.99) with the reference instrument for all aerosol types in environmental settings. In occupational settings, SPS30, AirBeam2, and PMS A003 exhibited high correlation (>0.96), but the OPC-N3 correlation varied (r = 0.88–1.00). Response significantly (p < 0.001) varied between environmental and occupational settings for most particle sizes and aerosol types. Biases varied by particle size and aerosol type. SPS30 and OPC-N3 exhibited low bias for environmental settings, but all of the sensors showed a high bias for occupational settings. For intra-instrumental precision, SPS30 exhibited high precision for salt for both settings compared to the other low-cost sensors and aerosol types. These findings suggest that SPS30 and OPC-N3 can provide a reasonable estimate of PM mass concentrations if calibrated differently for environmental and occupational settings using site-specific calibration factors.
机译:低成本光学粒子计数器有效地测量颗粒物质(PM)质量浓度一旦校准。通过使用参考仪器执行线性回归模型,可以通过使用参考仪器进行并排测量来建立传感器校准。但是,尚未证明环境和职业设置之间的校准差异。本研究在两个设置中评估了四种商用,低成本的PM传感器(OPC-N3,SPS30,Airbeam2和PMS A003)。测量三种气溶胶(盐,亚利桑那州道路粉尘和多α-烯烃-4油)的质量浓度,并与参考仪器进行比较。 OPC-N3和SPS30与环境环境中的所有气溶胶类型的参考仪器高度相关(R = 0.99)。在职业设置中,SPS30,AIRBEAM2和PMS A003表现出高相关(> 0.96),但OPC-N3相关性变化(r = 0.88-1.00)。对大多数粒度和气溶胶类型的环境和职业设置之间的反应显着(p <0.001)变化。粒径和气溶胶类型变化的偏差。 SPS30和OPC-N3表现出低偏置环境设置,但所有传感器都显示出职业环境的高偏见。对于仪器内精度,与其他低成本传感器和气溶胶类型相比,SPS30对两种环境表现出高精度。这些发现表明,如果使用特定于特别特有的校准因子,可以为环境和职业设置不同地校准时,SPS30和OPC-N3可以提供PM质量浓度的合理估计。

著录项

  • 期刊名称 Sensors (Basel Switzerland)
  • 作者单位
  • 年(卷),期 2021(21),12
  • 年度 2021
  • 页码 4146
  • 总页数 26
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

    机译:颗粒物质;OPC;OPC-N3;SPS30;AirBeam2;PMS A003;传感器校准;环境监测;职业监测;低成本传感器;

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号