首页> 美国卫生研究院文献>Journal of Clinical and Diagnostic Research : JCDR >Comparison of The Effect of Implant Abutment Surface Modifications on Retention of Implant-Supported Restoration with A Polymer Based Cement
【2h】

Comparison of The Effect of Implant Abutment Surface Modifications on Retention of Implant-Supported Restoration with A Polymer Based Cement

机译:聚合物基水泥对种植体基台表面改性对保留种植体支持的修复效果的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: In cement-retained implant-supported restoration it is important to gain adequate retention of definitive restoration as well as retrievability of prosthesis. The surface of the abutment, alloy of the restoration and the type of cement used influences the retention of the restoration. There is a need to analyze the influence of surface modifications of abutments on the retentive capabilities of provisional implant cements.>Purpose of study: To compare the effect of implant abutment surface modifications on retention of implant-supported restoration cemented with polymer based cement.>Materials and method: Thirty solid titanium implant abutments (ADIN), 8mm height, were divided into 3 groups. Ten abutments with retentive grooves (Group I) as supplied by the manufacturer, Ten abutments milled to 20 taper circumferentially (Group II), and Ten abutments milled and air-abraded with 110 μm aluminum oxide (Group III) were used in this study. Ni-Cr coping were casted for each abutment and polymer based cement was used to secure them to the respective abutments. Using a universal testing machine at a crosshead speed of 0.5 cm/minute, tensile bond strength was recorded (N).>Results: Mean tensile bond strength of Group I, II and III were found to be 408.3, 159.9 and 743.8 Newton respectively. The values were statistically different from each other (p<0.001).>Conclusion: Abutments with milled and sandblasted surface provide the highest retention followed by abutments with retentive grooves and then by abutments with milled surface when cast copings were cemented to implant abutments with polymer based cement.>Clinical implications: Retention of restoration depends on the surface of the abutment as well as the luting agents used. Incorporation of retentive grooves or particle abrasion can enhance retention especially in situation of short clinical crown.
机译:>背景:在水泥固位的种植体支持的修复物中,重要的是要充分保留确定的修复物和修复体。基台的表面,修复体的合金以及所用水泥的类型都会影响修复体的固位。有必要分析基台表面改性对临时种植体固位体固位力的影响。>研究目的:比较种植体基台表面改性对种植体支撑的骨水泥固位力的影响>材料和方法:将30个8mm高的固体钛种植体基台(ADIN)分为3组。在该研究中,使用了制造商提供的十个带有固位槽的基台(组I),周向铣削成20锥度的十个基台(组II)和铣削并用110μm氧化铝进行气磨的十个基台(组III)。为每个基台铸造Ni-Cr顶盖,并使用聚合物基水泥将其固定到各个基台上。使用万能试验机以0.5 cm / min的十字头速度记录拉伸粘结强度(N)。>结果:I,II和III组的平均拉伸粘结强度为408.3, 159.9和743.8牛顿。值在统计学上彼此不同(p <0.001)。>结论:带有铸造和喷砂表面的基台提供了最高的保持力,其次是带有保持槽的基台,然后是带有铸造顶盖的带有铣削表面的基台。 >临床意义:修复体的保留量取决于基台的表面以及所使用的诱剂。结合保持凹槽或颗粒磨损可以增强保持力,尤其是在临床冠较短的情况下。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号