首页> 美国卫生研究院文献>Animal Nutrition >Acid-insoluble ash is a better indigestible marker than chromic oxide to measure apparent total tract digestibility in pigs
【2h】

Acid-insoluble ash is a better indigestible marker than chromic oxide to measure apparent total tract digestibility in pigs

机译:酸不溶性灰分是比铬氧化物更好的难以解见的标记以测量猪中的表观总介质消化率

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of this study was to determine the apparent total tract digestibility (ATTD) of nutrients in cottonseed meal (CSM) and soybean meal (SBM) in simple carbohydrate and more complex wheat-based diets using 2 indigestible markers and total faecal collection. Twenty-five Large White × Landrace boars (57.8 kg) were randomly allocated to either a pure wheat diet, 40% CSM or SBM in either a sugar-starch- (1:1) or wheat-based diet for 18 d. Acid-insoluble ash (AIA) and chromic oxide (Cr2O3) were included in all diets as indigestible markers. Diets were offered (1,800 g/d per pig) in 3 meals/d from d 1 to 11 and 8 meals/d from d 12 to 17. On d 9, the pigs were moved to individual metabolism cages to allow total faecal collection. On d 18, the pigs were fed hourly for 8 h. After the 8th meal, pigs were anaesthetized and digesta sampled from the terminal ileum and rectum before lethal injection. There were no differences between ATTD of nitrogen (N) determined using AIA as a marker and measured by total faecal collection. On the other hand, the ATTD of N of diets containing CSM in sugar-starch- or wheat-based diets and the pure wheat diet determined using Cr2O3 as a marker was less (−3.11%, −4.46% and −6.59%; P < 0.001) than that measured by total faecal collection. The ATTD of N determined using AIA as a marker was highly correlated with that measured using total faecal collection (P < 0.001; R2 = 0.95). Similarly, the ATTD of N determined using Cr2O3 as a marker was correlated with that measured using total faecal collection, although the correlation was not quite as strong as using AIA (P < 0.001; R2 = 0.87). Also, the slope of the regression line and the intercept were closer to unity and zero for the relationship when the ATTD of N was determined using AIA compared to Cr2O3 as an indigestible marker. The ATTD of organic and dry matter behaved similarly. These data demonstrate that the basal diet and choice of indigestible marker can substantially influence the ATTD and that the use of AIA as an indigestible marker is more suitable than Cr2O3 in digestibility studies in pigs.
机译:本研究的目的是在简单的碳水化合物中确定棉籽粕(CSM)和大豆膳食(SBM)中营养物质的表观总养分(ATTD)和使用2个难以消化的标志物和总粪便收集的更复杂的小麦饮食。将25个大白×Landrace公猪(57.8千克)随机分配给纯小麦饮食,40%CSM或SBM,以糖 - 淀粉 - (1:1)或18天的小麦饮食。将酸不溶性灰分(AIA)和铬氧化物(CR2O3)包含在所有饮食中作为难以解见的标记。从D 1到11和8次餐饮/ D中提供的饮食(每猪1,800g / d),从D 12至17中的8次餐饮/ d。在D 9上,将猪移动到各个代谢笼中,以允许总粪便收集。在D 18上,猪每小时喂食8小时。在第8顿饭后,猪在致命注射前从末端回肠和直肠上取样并消化。使用AIA作为标记测定的氮气(N)的氮气(n)之间没有差异,并通过粪便总收集测量。另一方面,含有CSM的N的饮食ATTD含有CSM的糖 - 淀粉或小麦的饮食和使用Cr 2 O 3确定的纯小麦饮食的较少(-3.11%,-4.46%和-6.59%; p <0.001)通过粪便集合来测量。使用AIA确定为标记的N的attD与使用总粪便收集测量的高度相关(P <0.001; R2 = 0.95)。类似地,使用Cr2O3作为标记测定的N的attd与使用总粪便收集测量的N值相关,尽管相关性并不像使用AIa一样强(P <0.001; R2 = 0.87)。而且,回归线的斜率和截距更接近统一,并且当使用AIa与CR2O3作为难以消化的标记相比使用AIA的attd时的关系。有机和干物质的attd表现得同样。这些数据表明,基础饮食和对难析标记的选择可以基本上影响attd,并且使用AIa作为难析标记的使用比CR2O3更适合于猪中的消化性研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号