Acoustic Radiation Force Impulse Imaging of the Liver: Measurement of the Normal Mean Values of the Shearing Wave Velocity in a Healthy Liver

机译:肝脏的声辐射力脉冲成像:健康肝脏中剪切波速度的正常平均值的测量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

>AIM: To find the normal mean values of the liver elasticity/stiffness by Acoustic Radiation Force Impulse (ARFI) Elastography in healthy subjects.>Material and Method: This study was conducted on 137 healthy subjects without any known liver pathology or a history of jaundice by using the Siemens Acuson S2000TM Ultrasound machine with a convex probe . A routine ultrasound was also performed in each case, and the subjects with fatty liver changes or any other signs of a chronic liver pathology were excluded. In each subject, 10 measurements were taken and the median value of the 10 measurements was calculated, which was expressed in metres/sec (m/s). The inter quartile range method was used for the interpretation of the data. Only the measurements with an IQR of < 30% and a Success Rate (SR) of >60% were considered. The measurements were taken at 1-2 cm depth from the liver capsule through an intercostal approach, with the subject lying in the decubitus position. The mean ARFI values and the mean values according to the age and gender of the subjects were evaluated.>Result: Valid ARFI measurements were taken in 108/137 patients (78.83%). The mean value of the ARFI measurements in the normal individuals was 1.197±0.25 m/s. There were no significant differences between the mean ARFI values in men vs women (1.195±.25 vs. 1.199±0.26m/s, p = 0.939), and also among the different age groups (p>0.05).>Conclusion: In our study, the mean liver elasticity value (shearing wave velocity) which was obtained by ARFI in the healthy subjects was 1.197±0.25 m/s.
机译:>目标:通过声学辐射力脉冲(ARFI)弹性成像技术在健康受试者中找到肝脏弹性/刚度的正常平均值。>材料和方法:使用带凸探头的西门子Acuson S2000TM超声机,对137名没有已知肝脏病理或黄疸史的健康受试者进行了研究。在每种情况下,均进行常规超声检查,排除患有脂肪肝或其他任何慢性肝病体征的受试者。在每个受试者中,进行10次测量,并计算10次测量的中值,以米/秒(m / s)表示。四分位间距法用于解释数据。仅考虑IQR <30%和成功率(SR)> 60%的测量。通过肋间入路,在距肝囊1-2 cm深度处进行测量,受试者处于卧位。评估了平均ARFI值以及根据受试者年龄和性别的平均值。>结果:在108/137位患者中进行了有效的ARFI测量(78.83%)。正常人的ARFI测量平均值为1.197±0.25 m / s。男女之间的平均ARFI值之间没有显着差异(1.195±.25 vs. 1.199±0.26m / s,p = 0.939),并且在不同年龄组之间也没有显着差异(p> 0.05)。>结论:在我们的研究中,健康受试者通过ARFI获得的平均肝脏弹性值(剪切波速度)为1.197±0.25 m / s。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号