首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >Feasibility of Heart Rate and Respiratory Rate Estimation by Inertial Sensors Embedded in a Virtual Reality Headset
【2h】

Feasibility of Heart Rate and Respiratory Rate Estimation by Inertial Sensors Embedded in a Virtual Reality Headset

机译:虚拟现实耳机中嵌入式的心率和呼吸速率估算的可行性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Virtual reality (VR) headsets, with embedded micro-electromechanical systems, have the potential to assess the mechanical heart’s functionality and respiratory activity in a non-intrusive way and without additional sensors by utilizing the ballistocardiographic principle. To test the feasibility of this approach for opportunistic physiological monitoring, thirty healthy volunteers were studied at rest in different body postures (sitting (SIT), standing (STAND) and supine (SUP)) while accelerometric and gyroscope data were recorded for 30 s using a VR headset (Oculus Go, Oculus, Microsoft, USA) simultaneously with a 1-lead electrocardiogram (ECG) signal for mean heart rate (HR) estimation. In addition, longer VR acquisitions (50 s) were performed under controlled breathing in the same three postures to estimate the respiratory rate (RESP). Three frequency-based methods were evaluated to extract from the power spectral density the corresponding frequency. By the obtained results, the gyroscope outperformed the accelerometer in terms of accuracy with the gold standard. As regards HR estimation, the best results were obtained in SIT, with Rs2 (95% confidence interval) = 0.91 (0.81−0.96) and bias (95% Limits of Agreement) −1.6 (5.4) bpm, followed by STAND, with Rs2 = 0.81 (0.64−0.91) and −1.7 (11.6) bpm, and SUP, with Rs2 = 0.44 (0.15−0.68) and 0.2 (19.4) bpm. For RESP rate estimation, SUP showed the best feasibility (98%) to obtain a reliable value from each gyroscope axis, leading to the identification of the transversal direction as the one containing the largest breathing information. These results provided evidence of the feasibility of the proposed approach with a degree of performance and feasibility dependent on the posture of the subject, under the conditions of keeping the head still, setting the grounds for future studies in real-world applications of HR and RESP rate measurement through VR headsets.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号