首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >Testing the Performance of an Innovative Markerless Technique for Quantitative and Qualitative Gait Analysis
【2h】

Testing the Performance of an Innovative Markerless Technique for Quantitative and Qualitative Gait Analysis

机译:测试创新无价值技术进行定量和定性步态分析的性能

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Gait abnormalities such as high stride and step frequency/cadence (SF—stride/second, CAD—step/second), stride variability (SV) and low harmony may increase the risk of injuries and be a sentinel of medical conditions. This research aims to present a new markerless video-based technology for quantitative and qualitative gait analysis. 86 healthy individuals (mead age 32 years) performed a 90 s test on treadmill at self-selected walking speed. We measured SF and CAD by a photoelectric sensors system; then, we calculated average ± standard deviation (SD) and within-subject coefficient of variation (CV) of SF as an index of SV. We also recorded a 60 fps video of the patient. With a custom-designed web-based video analysis software, we performed a spectral analysis of the brightness over time for each pixel of the image, that reinstituted the frequency contents of the videos. The two main frequency contents (F1 and F2) from this analysis should reflect the forcing/dominant variables, i.e., SF and CAD. Then, a harmony index (HI) was calculated, that should reflect the proportion of the pixels of the image that move consistently with F1 or its supraharmonics. The higher the HI value, the less variable the gait. The correspondence SF-F1 and CAD-F2 was evaluated with both paired t-Test and correlation and the relationship between SV and HI with correlation. SF and CAD were not significantly different from and highly correlated with F1 (0.893 ± 0.080 Hz vs. 0.895 ± 0.084 Hz, p < 0.001, r2 = 0.99) and F2 (1.787 ± 0.163 Hz vs. 1.791 ± 0.165 Hz, p < 0.001, r2 = 0.97). The SV was 1.84% ± 0.66% and it was significantly and moderately correlated with HI (0.082 ± 0.028, p < 0.001, r2 = 0.13). The innovative video-based technique of global, markerless gait analysis proposed in our study accurately identifies the main frequency contents and the variability of gait in healthy individuals, thus providing a time-efficient, low-cost means to quantitatively and qualitatively study human locomotion.
机译:步态异常,如高步和阶梯频率/焦点(SF-stride /秒,CAD-Step /秒),脚级变异性(SV)和低调可能会增加伤害的风险,并且是医疗条件的哨兵。本研究旨在展示一种新的无标记视频技术,用于定量和定性步态分析。 86个健康个体(蜂蜜年龄32岁)在自我选择的步行速度下对跑步机进行了90次测试。我们通过光电传感器系统测量SF和CAD;然后,我们计算SF的平均±标准偏差(SD)和对象内的变化系数(CV)作为SV的索引。我们还记录了患者的60 FPS视频。利用定制设计的基于Web的视频分析软件,我们对图像的每个像素进行了随时间的亮度对亮度进行了频谱分析,从而重新安装了视频的频率内容。来自该分析的两个主要频率内容(F1和F2)应反映迫使/优势变量,即SF和CAD。然后,计算了一个和谐指数(HI),应该反映与F1或其Supraharmonics一致地移动的图像的像素的比例。高值越高,步态的变量越小。对应关系SF-F1和CAD-F2进行了配对的T检验和相关性,以及SV和HI之间的关系。 SF和CAD与F1的显着不同,与F1高(0.893±0.084Hz,P <0.001,R2 = 0.99)和F2(1.787±0.163Hz,P <0.79​​1±0.165 Hz,P <0.001 ,r2 = 0.97)。 SV为1.84%±0.66%,与HI显着和适度相关(0.082±0.028,P <0.001,R2 = 0.13)。我们研究中提出的创新视频基于视频的全局,无价值步态分析技术准确地识别了健康个体的步态的主要频率内容和可变性,从而提供了一定的节省的低成本手段来定量和定性地研究人类运动。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号