首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >Validity and Reliability of an Instrumented Treadmill with an Accelerometry System for Assessment of Spatio-Temporal Parameters and Impact Transmission
【2h】

Validity and Reliability of an Instrumented Treadmill with an Accelerometry System for Assessment of Spatio-Temporal Parameters and Impact Transmission

机译:具有加速度系统的仪表跑步机的有效性和可靠性用于评估时空参数和冲击变速器

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Running retraining programs focused on concurrent feedback of acceleration impacts have been demonstrated to be a good strategy to reduce running-related injuries (RRI), as well as to improve running economy and reduce acceleration impacts and injury running incidence. Traditionally, impacts have been registered by mean of accelerometers attached directly to the athletes, which is inaccessible to the entire population, because it requires laboratory conditions. This study investigated the validity and reliability of a new device integrated directly into the treadmill, compared to a traditional acceleration impact system. Thirty healthy athletes with no history of RRI were tested on two separate days over the instrumented treadmill (AccTrea) and simultaneously with an acceleration impact system attached to the participant (AccAthl). AccTrea was demonstrated to be a valid and reliable tool for measuring spatio-temporal parameters like step length (validity intraclass correlation coefficient (ICC) = 0.94; reliability ICC = 0.92), step time (validity ICC = 0.95; reliability ICC = 0.96), and step frequency (validity ICC = 0.95; reliability ICC = 0.96) during running. Peak acceleration impact variables showed a high reliability for the left (reliability ICC = 0.88) and right leg (reliability ICC = 0.85), and peak impact asymmetry showed a modest validity (ICC = 0.55). These results indicated that the AccTrea system is a valid and reliable way to assess spatio-temporal variables, and a reliable tool for measuring acceleration impacts during running.
机译:已经表明,朝向加速影响的并发反馈的运行培训计划是一种良好的策略,以减少与武流遭遇的伤害(RRI),以及改善运行经济,降低加速影响和伤害发生率。传统上,通过直接连接到运动员的加速度计的平均值登记的影响,这对整个人口无法进入,因为它需要实验室条件。与传统的加速度影响系统相比,本研究调查了直接整合到跑步机上的新设备的有效性和可靠性。在仪表跑步机(ACCTREA)的两个单独的日子上,在两个健康运动员上进行了三十个健康运动员,并同时与参与者(ACCATHL)附加的加速度影响系统同时进行测试。 acctrea被证明是用于测量步长度的时空参数的有效可靠的工具,如步长(有效性跨越相关系数(ICC)= 0.94;可靠性ICC = 0.92),步进时间(有效性ICC = 0.95;可靠性ICC = 0.96),运行期间,阶梯频率(有效性ICC = 0.95;可靠性ICC = 0.96)。峰值加速度影响变量对左侧的可靠性高(可靠性ICC = 0.88)和右腿(可靠性ICC = 0.85),峰值冲击不对称性显示出谦虚的有效性(ICC = 0.55)。这些结果表明,Acctrea系统是评估时空变量的有效和可靠的方法,以及用于在运行期间测量加速度影响的可靠工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号