首页> 美国卫生研究院文献>Journal of Clinical Medicine >Transcatheter Aortic Valve Replacement Is Associated with Less Oxidative Stress and Faster Recovery of Antioxidant Capacity than Surgical Aortic Valve Replacement
【2h】

Transcatheter Aortic Valve Replacement Is Associated with Less Oxidative Stress and Faster Recovery of Antioxidant Capacity than Surgical Aortic Valve Replacement

机译:经导管主动脉瓣置换术比手术主动脉瓣置换术具有更低的氧化应力和更快的抗氧化能力恢复能力

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The objective of this study was to compare oxidative stress indices in 24 patients (mean ± SD age 71 ± 13 years) undergoing surgical aortic valve replacement (SAVR) versus transcatheter aortic valve replacement (TAVR). Serum total antioxidant capacity (TAC), copper/zinc ratio (Cu/Zn), activity of lactate dehydrogenase (LDH), and thiobarbituric acid reactive substances (TBARS) were assessed at four different time-points: pre-procedure, immediately post-procedure, and one day and two days after the procedure. All oxidative stress parameters were comparable in both groups pre-procedure. TAC decreased significantly when assessed immediately after procedures in both groups (p < 0.001); however, the magnitude of the reduction was more pronounced after SAVR (88% decrease from baseline: 1.8 ± 0.1 vs. 0.2 ± 0.03 mM) compared to TAVR procedures (53% decrease from baseline: 1.9 ± 0.1 vs. 1.0 ± 0.1 mM; p < 0.001). TAC returned to baseline two days after TAVR in all patients, but was still reduced by 55% two days after SAVR. In concordance, TBARS levels and Cu/Zn ratio increased significantly with maximum levels immediately after procedures in both groups (p < 0.001), but the magnitude of the increase was significantly higher in SAVR compared to TAVR (TBARS: 3.93 ± 0.61 µM vs. 1.25 ± 0.30 µM, p = 0.015; Cu/Zn ratio: 2.33 ± 0.11 vs. 1.80 ± 0.12; p < 0.001). Two days after the procedure, TBARS levels and the Cu/Zn ratio returned to baseline after TAVR, with no full recovery after SAVR. TAVR is associated with a lesser redox imbalance and faster recovery of antioxidant capacity compared to SAVR.
机译:这项研究的目的是比较接受手术主动脉瓣置换术(SAVR)与经导管主动脉瓣膜置换术(TAVR)的24例患者(平均±SD年龄71±13岁)的氧化应激指数。在四个不同的时间点对血清总抗氧化剂能力(TAC),铜/锌比(Cu / Zn),乳酸脱氢酶(LDH)活性和硫代巴比妥酸反应性物质(TBARS)进行了评估:术前,术后立即程序,以及程序后一天和两天。两组术前所有氧化应激参数均相当。两组术后均立即评估,TAC显着降低(p <0.001);然而,与TAVR程序相比,SAVR后的降低幅度更为明显(比基线降低88%:1.8±0.1 vs. 0.2±0.03 mM)(比基线降低53%:1.9±0.1 vs. 1.0±0.1 mM; p <0.001)。所有患者在TAVR后两天,TAC均恢复至基线,但在SAVR后两天,TAC仍降低了55%。一致的是,两组手术后TBARS水平和Cu / Zn比值随最高水平显着增加(p <0.001),但SAVR的增加幅度明显高于TAVR(TBARS:3.93±0.61 µM vs. TAVR。 1.25±0.30 µM,p = 0.015; Cu / Zn比:2.33±0.11对1.80±0.12; p <0.001)。手术后两天,TAVR后TBARS水平和Cu / Zn比值恢复到基线,而SAVR后未完全恢复。与SAVR相比,TAVR与较少的氧化还原失衡和更快的抗氧化能力恢复有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号