首页> 美国卫生研究院文献>Dentistry Journal >Three-Year Retrospective Comparative Study between Implants with Same Body-Design but Different Crest Module Configurations
【2h】

Three-Year Retrospective Comparative Study between Implants with Same Body-Design but Different Crest Module Configurations

机译:具有相同车身设计但不同CREST模块配置的植入物之间的三年追溯研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Crest module can be defined as the portion of a two-piece implant designed to retain the prosthetic components and to allows the maintenance of the peri-implant tissues in the transition zone. Aim: To evaluate the three-year after loading clinical and radiographic data, collected from patients that received a prosthetic rehabilitation on conical connection implants with partial machined collar (PMC; CC Group) and same body-designed implants, with flat-to-flat connection and groovy neck design (FC Group). Materials and Methods: A retrospective chart review of previously collected data, including documents, radiographs, and pictures of patients who received at least one implant-supported restoration on NobelReplace CC PMC or NobelReplace Tapered Groovy implants was performed. Patients with at least three years of follow-up after final loading were considered for this study. Outcomes measures were implant and prosthesis failures, any biological or technical complications, marginal bone loss. Results: Eight-two patients (44 women, 38 men; average age 55.6) with 152 implants were selected and divided in two groups with 77 (CC group) and 75 (FC group), respectively. Three years after final loading, one implant in CC group failed (98.7% survival rate), while no implants failed in FC group (100% survival rate). One restoration failed in CC group (98.7% survival rate) with no restoration failing in the FC one (100% survival rate). Differences were not statistically significant (p = 1.0). Three years after final loading, mean marginal bone loss was 0.22 ± 0.06 mm (95% CI 0.2–0.24) in CC group and 0.62 ± 0.30 mm (95% CI 0.52–0.72) in FC group. The difference was statistically significant (0.40 ± 0.13 mm; 95% CI 0.3–0.5; p = 0.003). Conclusion: with the limitation of this retrospective comparative study, implants with conical connection and partial machined collar seem to achieve a trend of superior outcomes if compared with implants with flat connection and groovy collar design.
机译:嵴模块可以定义为双件式植入物的部分,该植入物设计用于保留假体部件并允许在过渡区中维持围植入组织。目的:评估加载临床和放射线数据后的三年,从患者收集,接受锥形连接植入物的假体康复,部分加工衣领(PMC; CC组)和相同的车身设计的植入物,具有平坦的连接和沟槽颈部设计(FC组)。材料和方法:进行先前收集的数据的回顾性图表审查,包括在Nobelreplace CC PMC或Nobelreplace锥形植入物上收到至少一个植入物支持的恢复的患者的文件,射线照相和图片。考虑到这项研究后,考虑了最终装载后至少三年后的患者。结果措施是植入物和假体失败,任何生物或技术并发症,边际骨质损失。结果:八二名患者(44名女性,38名男子;平均年龄55.6)分别选择了152个植入物,分别分为两组,分别分为77(CC组)和75(FC组)。最后一次载入三年后,CC组中的一种植入物失败(生存率为98.7%),而FC组内没有植入物失效(100%存活率)。在CC组(98.7%存活率)中,一种恢复失败,FC ONE(存活率100%)没有恢复。差异没有统计学意义(p = 1.0)。最后一次装载后三年,CC组中的平均边缘骨损失为0.22±0.2-0.24毫米(95%CI 0.2-0.24),在FC组中为0.62±0.30mm(95%CI 0.52-0.72)。差异有统计学意义(0.40±0.13mm; 95%CI 0.3-0.5; p = 0.003)。结论:随着该回顾性比较研究的限制,与植入物与具有平坦连接和沟槽设计的植入物相比,具有锥形连接和部分加工套环的植入物似乎达到了优越的结果的趋势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号