首页> 美国卫生研究院文献>Biology of Sport >Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes
【2h】

Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes

机译:高校运动员跳跃高度的可穿戴技术的设备间可靠性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of this study was to evaluate the inter-device reliability of three VERT devices (Mayfonk Athletic, Florida, USA) when worn on the waist (W), left-hip (LH), and right-hip (RH) during single- and double-leg counter movement jumps (CMJ) in collegiate athletes. Thirty-two female and twenty-eight male NCAA Division II athletes (n = 60) participated in the present study. Jump height (JH) values for double-leg CMJs were analyzed by each device using a one-way repeated measures ANOVA whereas a 2 (jump leg) x 3 (wear location) repeated measures ANOVA was employed to evaluate single-leg CMJs. Reliability of the VERT devices were based upon intraclass correlation coefficients (ICC). Double-leg CMJs revealed an excellent ICC between all three VERT devices (ICC = 0.969). However, JH for RH and LH (45.69 ± 9.84 and 45.82 ± 10.45 cm, respectively) were on average lower than W (50.44 ± 12.37cm; both p < 0.001). The ICCs were excellent for right- and left-leg CMJs (ICC = 0.939 and 0.941, respectively). However, an interaction was observed (p < 0.001). No differences existed for left- or right-leg when VERT was worn on the waist. However, JH was higher when VERT devices were worn on the opposite hip of the jump leg (i.e., LH>RH for right-leg CMJs; RH>LH for leftleg CMJs; all p < 0.001). Results suggest that LH and RH are interchangeable for double-leg CMJs, but not with waist despite excellent reliability. In addition, all wear locations provided excellent ICCs for single-leg CMJs. However, waist provides more consistent JH values for right- and left-leg CMJs while RH and LH show more variability.
机译:本研究的目的是评估三个VERT器件(Mayfonk Atheric,Florida,USA)的设备间可靠性,当在单一的腰部(W),左臀部(LH)和右臀部(RH)上磨损时 - 在大学运动员中的双腿计数器运动跳跃(CMJ)。三十二名女性和二十八名男性NCAA分部II运动员(n = 60)参加了本研究。使用单向重复测量ANOVA分析双腿CMJS的跳高(JH)值,而使用单向重复测量ANOVA,而使用2(跳腿)×3(磨损位置)反复测量ANOVA来评估单腿CMJ。 VERT器件的可靠性基于脑内相关系数(ICC)。双腿CMJS在所有三个VERT器件(ICC = 0.969)之间显示出优异的ICC。然而,平均低于W(50.44±12.37厘米,rh和lh(45.69±9.84和45.82±10.45厘米;均为p <0.001)。 ICCS对于右腿和左腿CMJS(ICC = 0.939和0.941)非常好。但是,观察到相互作用(P <0.001)。当腰部佩戴在腰部时,左腿或右腿没有差异。然而,当跳动腿的相对臀部佩戴在跳动腿的相对臀部(即,右腿Cmjs的RH)上佩戴jH; RH> LH for leftleg cmjs;所有p <0.001)。结果表明,尽管具有优异的可靠性,但LH和RH可互换,而且没有腰部。此外,所有磨损位置都为单腿CMJS提供了优异的ICC。但是,腰部为右腿和左腿CMJS提供更一致的JH值,而RH和LH显示出更多的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号