This study aims to investigate the fixation strength of unilateral cortical bone trajectory screw fixation (UCBT) and UCBT with contralateral translaminar facet screw fixation (UCBT-TFS) by repeating the verification of three finite element models. Three healthy female models of the lumbosacral spine were constructed. For each of them, four transforaminal lumbar interbody fusion (TLIF) models with the following instruments were created: bilateral traditional trajectory pedicle screw fixation (TT), bilateral cortical bone trajectory screw fixation (CBT), UCBT, and UCBT-TFS. A 150-N compressive load with 10 N/m moments was applied to simulate flexion, extension, lateral bending, and axial rotation. The range of motion (ROM), the stress of the cages, and the stress of the posterior fixations were compared. TT and UCBT-TFS had a similar low ROM compared to the intact models, and CBT showed a higher ROM in lateral bending. UCBT resulted in the highest ROM under all loading conditions, especially in lateral bending (116% and 170% greater than TT in left bending and right bending). UCBT induced a significant increase in the peak stress of cages and instruments, followed by CBT and UCBT-TFS, and the lowest mean values were observed for TT. Among the four different fixation techniques, TT offered the highest fixation strength and lowest implant stress, followed by UCBT-TFS and CBT, while UCBT was the least stable and resulted in increased stress of the screws and cages. UCBT-TFS improved biomechanical stability and appeared to be a less invasive alternative in well-selected patients with single-level TLIF.
机译:本研究旨在通过重复三个有限元模型的验证来研究单侧皮质骨轨迹螺钉固定(UCBT)和UCBT)和UCBT-TFS的UCBT的固定强度。建造了三个健康的腰骶脊柱的女性模型。对于每个人来说,创建了四个横向挡泥板椎体椎间体融合(TLIF)模型,具有以下仪器:双边传统轨迹椎弓根螺钉固定(TT),双侧皮质骨轨迹螺钉固定(CBT),UCBT和UCBT-TFS。应用具有10n / m矩的150n压缩载荷,用于模拟屈曲,延伸,横向弯曲和轴向旋转。比较了运动范围(ROM),笼的应力和后固定的应力。与完整模型相比,TT和UCBT-TFS具有相似的低ROM,CBT在横向弯曲中显示出更高的ROM。 UCBT导致所有装载条件下的最高ROM,特别是在横向弯曲(116%和170%大于TT的左弯曲和右弯曲)下。 UCBT诱导笼子和仪器的峰值应力的显着增加,然后是CBT和UCBT-TFS,并且观察到TT的最低平均值。在四种不同的固定技术中,TT提供了最高的固定强度和最低植入物应力,然后是UCBT-TFS和CBT,而UCBT是最不稳定的,导致螺钉和笼的应力增加。 UCBT-TFS改善了生物力学稳定性,并且似乎是单层TLIF精选患者的较少侵袭性替代品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号