首页> 美国卫生研究院文献>Diagnostics >A Comparison of a Standard Macintosh Blade Laryngoscope Pentax-AWS Videolaryngoscope and Intubrite Videolaryngoscope for Tracheal Intubation in Manikins in Sitting and Prone Positions: A Randomized Cross-Over Study
【2h】

A Comparison of a Standard Macintosh Blade Laryngoscope Pentax-AWS Videolaryngoscope and Intubrite Videolaryngoscope for Tracheal Intubation in Manikins in Sitting and Prone Positions: A Randomized Cross-Over Study

机译:标准Macintosh叶片喉镜Pentax-AWS videolaryngoscope和Intubrite videolaryngoscope在坐在和俯卧位的Manikins中的气管插管:随机交叉研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: Intubation of a patient in different positions may be done not only in emergency settings, but also in routine anesthesia (e.g., prone position for lumbar spine surgery). Methods: The aim of the study was to compare the classic Macintosh blade laryngoscope with two videolaryngoscopes: the Pentax-AWS and the Intubrite in a simulated scenario of a manikin placed in a sitting and prone position. Additionally, intubation with the use of all three devices was performed in a standard supine position as the control group. The time of intubation and the pressure exerted on the tongue was assessed. The ANOVA Friedman (analysis of variance) and Wilcoxon with Bonferroni correction tests were used for statistical analysis. Results: The time of intubation in a prone position was significantly shorter for the Pentax-AWS videolaryngoscope compared to the Macintosh and the Intubrite. There were no significant differences in the obtained results of the evaluated devices in sitting and standard positions. The lowest pressure exerted on the tongue was with the Pentax-AWS, followed by the Intubrite and the Macintosh laryngoscopes. Conclusions: The use of the Pentax-AWS was associated with faster tracheal intubation, creating lower pressure on tongue when compared with standard Macintosh and Intubrite laryngoscopes in both prone and sitting positions.
机译:背景技术:患者在不同位置的插管不仅可以在急诊环境中进行,而且可以在常规麻醉中进行(例如,腰椎手术的易于置位)。方法:该研究的目的是将经典的Macintosh刀片喉镜与两个视频诊断进行比较:Pentax-AWS和Intubrite在坐在坐姿和俯卧位的Manikin的模拟场景中。另外,使用所有三个设备的插管以标准仰卧位作为对照组进行。预防时间和舌头上施加的压力进行了评估。 Anova Friedman(对方差分析)和Wilcoxon具有Bonferroni校正试验用于统计分析。结果:与Macintosh和Intubrite相比,Pentax-AWS videolaryngoscops的插管时间越短。在坐标和标准位置的评估装置的所得结果中没有显着差异。在舌头上施加的最低压力与Pentax-AWS一起,其次是intubrite和Macintosh喉镜。结论:与俯卧位和坐姿的标准Macintosh和Intubrite Larynopeps相比,使用了Pentax-AWS的使用更快,在舌头上产生较低的压力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号