Determination of leukocyte counts in cerebrospinal fluid with a disposable plastic hemocytometer

机译:用一次性塑料血细胞计数器测定脑脊液中白细胞计数

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Manual microscopic cell counting in a Fuchs‐Rosenthal (FR) chamber has been the gold standard for quantification of leukocytes in cerebrospinal fluid (CSF). However, for accurate determination of the number and differentiation of cells by chamber counting, hemocytometers must be prepared carefully and kept clean. Improper fitting of the chamber and coverslip changes the volume of sample introduced into the chamber well. Moreover, because conventional hemocytometers are used repeatedly and are breakable, there is a risk of exposure to potentially infectious material. To address these issues, disposable plastic hemocytometers have been developed. However, the accuracy, precision, and clinical usefulness of disposable chambers for CSF cells counting have not been determined. In the present study, we evaluated use of a disposable plastic counting chamber (C‐Chip DHC‐F01) by comparing its performance with that of an FR chamber for counting of CSF specimens and cell suspensions. Within‐run precision of C‐Chip counting was comparable or superior to that of FR chamber counting, and excellent correlation between cell counts obtained with the C‐Chip chamber and FR chamber was observed. However, C‐Chip chambers that were kept at 4°C yielded significantly low cell counts. The disposable hemocytometer will reduce the risk of exposure to potentially infectious material. However, use of C‐Chip chambers should be avoided in cold environments. J. Clin. Lab. Anal. 21:282–285, 2007. © 2007 Wiley‐Liss, Inc.
机译:在Fuchs-Rosenthal(FR)室中进行手动显微细胞计数已成为定量脑脊髓液(CSF)中白细胞的金标准。但是,为了通过室计数准确确定细胞的数量和分化,必须精心准备血细胞计数器并保持清洁。腔室和盖玻片的安装不当会改变引入腔室的样品的体积。此外,由于常规的血细胞计数器被重复使用并且易碎,因此存在暴露于潜在感染性物质的风险。为了解决这些问题,已经开发了一次性塑料血细胞计数器。然而,尚未确定用于CSF细胞计数的一次性腔室的准确性,准确性和临床实用性。在本研究中,我们通过比较一次性塑料计数室(C-Chip DHC-F01)与FR室对CSF标本和细胞悬液进行计数的性能,评估了其使用情况。 C-Chip计数的运行内精度与FR室计数相当或更高,并且观察到通过C-Chip室和FR室获得的细胞计数之间具有极好的相关性。但是,保持在4°C的C-Chip室的细胞数非常低。一次性血细胞计数器将减少暴露于潜在感染性物质的风险。但是,应避免在寒冷环境中使用C型芯片腔室。 J.临床实验室肛门21:282–285,2007.©2007 Wiley-Liss,Inc.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号