Real-time ultrasound imaging (US) to measure abdominal muscle dimensions has aided low back pain rehabilitation and research. Notwithstanding, ultrasound imaging measurement of transversus abdominis muscle activation in chronic low back pain populations has been characterized by variable and generally suboptimal intra-observer reliability. Methodological deficiencies of ‘freehand’ ultrasound imaging are uncontrolled probe–skin pressure, inclination and roll of the probe. Despite previous attempts to standardize these parameters, intra-observer reliability in chronic low back pain was poor to moderate (0.32–0.62). Therefore, a standardized method that controls and records probe force, inclination and roll during ultrasound imaging may optimize measurement reliability in chronic low back pain. This pilot study investigated utility, standardization and intra-observer reliability of ultrasound imaging transversus abdominis thickness measurement in chronic low back pain patients (n = 17). Transversus abdominis imaging over two separate measurement sessions was conducted using a novel method to standardize probe parameters. Resting and contracted transversus abdominis thickness, and transversus abdominis activation measurements were obtained from duplicate paired images (n = 68). Intra-class correlation coefficients were reported with 95% confidence intervals. Transversus abdominis thickness at rest (intra-class correlation coefficient = 0.97 confidence interval: 0.93, 0.99), when contracted (intra-class correlation coefficient = 0.99 confidence interval: 0.97, 0.99) and transversus abdominis activation (intra-class correlation coefficient = 0.93 confidence interval: 0.81, 0.97) measurements were highly reliable. Ultrasound imaging of transversus abdominis using the novel standardized ultrasound imaging method produced highly reliable intra-observer transversus abdominis measurements, superior to ‘freehand’ ultrasound imaging, despite the physical limitations typically associated with a chronic low back pain population. Unique standardizing ranges for ‘probe force device’ probe parameters were obtained. This novel standardized ultrasound imaging method may optimize transversus abdominis activation assessment in chronic low back pain and other populations, aiding future research.
机译:实时超声成像(US)测量腹肌尺寸有助于腰痛的康复和研究。尽管如此,超声成像测量慢性下腰痛人群中横贯腹肌的激活的特点是观察者内部的信度各不相同,且总体上次优。 “徒手”超声成像的方法学缺陷是无法控制的探头-皮肤压力,探头的倾角和倾角。尽管先前曾尝试对这些参数进行标准化,但慢性下腰痛的观察者内部可靠性差至中度(0.32-0.62)。因此,在超声成像过程中控制和记录探查力,倾斜度和侧倾的标准化方法可以优化慢性下腰痛的测量可靠性。这项前瞻性研究调查了慢性腰背痛患者(n = 17)的超声成像横贯腹膜厚度测量的效用,标准化和观察者内部可靠性。使用一种新颖的方法对腹部参数进行两次横向测量,以标准化探针参数。从重复的成对图像中获得静止和收缩的腹横肌厚度,以及腹横肌激活测量值(n = 68)。类内相关系数报告为95%置信区间。收缩时腹横肌厚度(类内相关系数= 0.97置信区间:0.93,0.99),收缩时(类内相关系数= 0.99置信区间:0.97,0.99)和横腹腹肌激活(类内相关系数= 0.93)置信区间:0.81、0.97)测量结果高度可靠。尽管通常与慢性下腰痛人群相关的身体限制,但使用新型标准化超声成像方法对横贯腹腔进行超声成像可产生高度可靠的观察者横贯腹腔测量,优于“徒手式”超声成像。获得了“测头装置”测头参数的唯一标准化范围。这种新颖的标准化超声成像方法可以优化慢性下腰痛和其他人群的横贯腹部激活评估,以帮助将来的研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号