首页> 美国卫生研究院文献>Neurophotonics >In vivo validation of cerebral near-infrared spectroscopy: a review
【2h】

In vivo validation of cerebral near-infrared spectroscopy: a review

机译:脑近红外光谱的体内验证:综述

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We summarize the available validation of cerebral near-infrared spectroscopy (NIRS) oximetry to inform future validation strategies. In particular, to establish a way forward in the assessment of NIRS instrumentation for future randomized trials, a systematic literature search is performed. The records are screened and abstracts are assessed to select studies fulfilling our inclusion criteria. Twenty-two pediatric and 28 adult studies are analyzed after exclusion of three articles in each group. All studies compare regional cerebral tissue oxygenation measured by cerebral NIRS to invasive measurement of central or jugular venous oxygen saturation. In studies without Bland–Altman plots, we extracted data from scatter plots enabling estimation of mean difference (MD), standard deviation (SD), and limits of agreement (LOA). To assess the agreement between (regional cerebral tissue oxygenation) estimated by NIRS and by blood samples, weighted averages of the MDs and SDs from each study are calculated. We found a fair agreement between the overall mean of cerebral tissue oxygenation and the mean of a reference value measured by co-oximetry whatever NIRS instrument or site of blood sampling used. Cerebral oxygenation overestimates the reference at low values, some instruments apparently more than others. Thus, a high degree of scatter and a lack of a good reference method complicate validation of NIRS. It is difficult to draw any firm conclusions despite the large number of studies, and the result of this review leaves us questioning if more of such validation studies of cerebral NIRS oximetry are really needed. Furthermore, the combination of lack of validation and poor repeatability is an important issue when designing a randomized clinical trial of implementing cerebral NIRS oximetry into clinical care.
机译:我们总结了大脑近红外光谱(NIRS)血氧饱和度的可用验证,以告知未来的验证策略。尤其是,要确定在评估NIRS仪器以进行未来随机试验时的前进方法,需要进行系统的文献检索。筛选记录并评估摘要以选择符合我们纳入标准的研究。在排除每组三篇文章后,分析了22项儿科研究和28项成人研究。所有研究都将通过脑部NIRS测量的局部脑组织氧合与对中央或颈静脉血氧饱和度的侵入性测量进行比较。在没有Bland–Altman图的研究中,我们从散点图中提取了数据,从而可以估计均值差(MD),标准差(SD)和一致限(LOA)。为了评估由NIRS估计的(区域性脑组织氧合)与血液样本之间的一致性,计算每个研究的MD和SD的加权平均值。我们发现,无论使用NIRS仪器还是采血部位,大脑组织氧合的总体平均值与通过共氧测定法测量的参考值的平均值之间都存在合理的一致性。脑氧合低估了参考值,某些仪器显然比其他仪器高。因此,高度分散和缺乏好的参考方法使NIRS的验证复杂化。尽管有大量的研究,但很难得出任何确凿的结论,而本综述的结果使我们提出疑问,是否确实需要进行更多的关于大脑NIRS血氧饱和度的验证研究。此外,在设计一项将脑NIRS血氧测定法应用于临床护理的随机临床试验时,缺乏验证和可重复性差的问题是一个重要的问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号