Accuracy of Three Impression Materials on the Totally Edentulous Maxilla: In Vitro/In Silico Comparative Analysis

机译:完全相同的上颌骨上三种印模材料的准确性:体外/计算机比较分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

Background: This study was aimed at comparing the accuracy of impressions of a reference typodont (RT) reproducing a totally edentulous maxilla made with three impression materials: polysulfide, polyether, and polyvinyl-siloxane. Methods: The RT was scanned using a desktop scanner, obtaining a reference scan. Ten impressions for each of the three tested materials were made using a mechanical device with a standardized and consistent modality. A laboratory scanner performed the digitization of each impression. We produced digital models by processing “in reverse” the scans of the physical impressions using a dedicated software, obtaining three groups (n = 10), respectively. The groups were titled: “polysulfide,” “polyvinyl-siloxane,” and “polyether”. The scans in .stl format were imported into Geomagic Control X and then compared to RT to evaluate the accuracy of each scan by calculating trueness and precision in µm. Recorded data were subjected to descriptive statistics. Results: Trueness (arithmetic proximity) values (95%CI) were: polysulfide = 249.9 (121.3–378.5), polyvinyl-siloxane = 216.8 (123.1–310.6), polyether = 291.1 (219.9–362.3). Precision values (95% CI) were: polysulfide = 261.9 (108.8–415), polyvinyl-siloxane = 209.4 (111.9–306.8), polyether = 283 (227.9–338.1). Statistically significant differences were not detected between the means of the experimental groups, both for trueness and precision. Conclusions: The accuracy of the scans obtained from polyvinyl-siloxane, polysulfide, and polyether impressions can be considered comparable in a fully edentulous maxilla.
机译:背景:这项研究旨在比较参考台风(RT)的印模精度,该参考印模可复制由三种印模材料制成的完全无牙上颌:聚硫化物,聚醚和聚乙烯基硅氧烷。方法:使用台式扫描仪扫描RT,获得参考扫描。使用具有标准化且一致的模态的机械设备,对三种测试材料中的每一种都产生了十次印象。实验室扫描仪对每个印痕进行数字化处理。我们通过使用专用软件对物理印象的扫描进行“反向”处理来生成数字模型,分别获得三组(n = 10)。这些组的标题为:“聚硫化物”,“聚乙烯基硅氧烷”和“聚醚”。将.stl格式的扫描导入到Geomagic Control X中,然后与RT进行比较,以通过计算真实性和以µm为单位的精度来评估每次扫描的准确性。对记录的数据进行描述性统计。结果:真实性(算术近似)值(95%CI)为:多硫化物= 249.9(121.3–378.5),聚乙烯基硅氧烷= 216.8(123.1–310.6),聚醚= 291.1(219.9–362.3)。精度值(95%CI)为:聚硫化物= 261.9(108.8–415),聚乙烯基硅氧烷= 209.4(111.9–306.8),聚醚= 283(227.9–338.1)。无论是真实性还是准确性,均未在实验组的方法之间检测到统计学上的显着差异。结论:在完全无牙颌的上颌中,从聚乙烯基硅氧烷,聚硫化物和聚醚压痕获得的扫描准确性可被认为是可比的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号