首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Performance of a New Rapid Assay for Detection of Trichomonas vaginalis
【2h】

Performance of a New Rapid Assay for Detection of Trichomonas vaginalis

机译:一种新的快速检测阴道毛滴虫的方法的性能

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Trichomonas vaginalis infection is highly prevalent, may have serious health consequence, and is readily treatable. However, screening has been limited by currently available tests, which tend to be insensitive, expensive, or require a delay before results are reported. The XenoStrip-Tv (Xenotope Diagnostics, Inc., San Antonio, Tex.) was evaluated on vaginal swab specimens from 936 women attending sexually transmitted disease clinics in Seattle, Wash. (n = 497), and Birmingham, Ala. (n = 439). T. vaginalis prevalence by culture (InPouch; Biomed) was 8.7% in Seattle and 21.0% in Birmingham. Compared to culture, the XenoStrip assay in Seattle was 76.7% (95% confidence interval [95% CI] = 61.4 to 88.2) sensitive and 99.8% (95% CI = 98.8 to 99.9) specific, and in Birmingham it was 79.4% (95% CI = 69.6 to 87.1) sensitive and 97.1% (95% CI = 94.8 to 98.6) specific. The positive predictive values were 97.1% in Seattle and 87.9% in Birmingham; the negative predictive values were 97.8 and 94.7%, respectively. Rapid test performance did not vary by vaginal symptoms or by the presence of other vaginal or cervical syndromes or infections. The sensitivity did vary by day of culture-positive result, with a 71% decline in XenoStrip sensitivity for every additional day delay until T. vaginalis was first detected in cultures (odds ratio = 0.29, 95% CI = 0.18 to 0.49). The rapid assay was more sensitive than wet preparation microscopy (78.5% versus 72.4% [P = 0.04]) but was less specific (98.6% versus 100% [P = 0.001]). The XenoStrip rapid assay is well suited for use in settings with a moderately high prevalence of T. vaginalis infection, particularly when microscopy is not practical.
机译:阴道滴虫感染非常普遍,可能对健康造成严重影响,并且易于治疗。但是,筛选受到当前可用测试的限制,该测试往往不敏感,昂贵或需要延迟才能报告结果。 XenoStrip-Tv(Xenotope Diagnostics,Inc.,得克萨斯州圣安东尼奥市)在华盛顿州西雅图市(n = 497)和阿拉巴马州伯明翰市(n = 497)参加性传播疾病诊所的936名妇女的阴道拭子标本上进行了评估。 439)。在西雅图,经培养的阴道锥虫患病率(InPouch; Biomed)为8.7%,伯明翰为21.0%。与文化相比,西雅图的XenoStrip检测灵敏度为76.7%(95%置信区间[95%CI] = 61.4至88.2),灵敏度为99.8%(95%CI = 98.8至99.9),伯明翰为79.4%(95%CI = 98.8至99.9)。敏感度为95%CI = 69.6至87.1),特异性为97.1%(95%CI = 94.8至98.6)。西雅图和伯明翰的阳性预测值分别为97.1%和87.9%;阴性预测值分别为97.8和94.7%。快速测试性能不会因阴道症状或其他阴道或宫颈综合症或感染而异。敏感性确实随培养阳性结果的天数而变化,直到开始在培养物中首次检测到阴道毛滴虫时,XenoStrip敏感性每隔一天延迟下降71%(几率= 0.29,95%CI = 0.18至0.49)。快速测定比湿制备显微镜更灵敏(78.5%对72.4%[P = 0.04]),但特异性较低(98.6%对100%[P = 0.001])。 XenoStrip快速测定法非常适合用于阴道锥虫感染程度较高的环境中,特别是在不可行显微镜检查时。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号