When the flat-bottomed, glass-stoppered, round bottle traditionally used to make VDRL antigen was discontinued, an appropriate substitute was needed. Although many laboratories have switched to one of the other nontreponemal tests for syphilis serology screening, the VDRL test remains the only approved procedure for testing spinal fluids of patients with possible neurosyphilis. We tested 25-ml glass-stoppered, convex-bottomed Erlenmeyer flasks to determine if these could be used as appropriate substitutes. We tested 52 reactive sera and 54 nonreactive sera by using one reference antigen prepared in the traditional flat-bottomed bottles and five antigens prepared in the Erlenmeyer flasks. Results with all serum samples were comparable. We also tested two lots of a commercial antigen plus an additional lot of reference antigen. Again there was no difference in the reactivity of the antigens. Therefore, we conclude that 25-ml glass-stoppered Erlenmeyer flasks can be used as an appropriate substitute for glass-stoppered, flat-bottomed, round glass bottles in the making of VDRL antigen.
机译:当不再使用传统上用来制造VDRL抗原的平底玻璃塞圆瓶时,需要合适的替代品。尽管许多实验室已转换为梅毒血清学筛查的其他非四方性检验之一,但VDRL检验仍是唯一可行的检验可能的神经梅毒患者脊髓液的方法。我们测试了25毫升玻璃塞,凸底锥形烧瓶,以确定它们是否可以用作合适的替代品。通过使用在传统平底瓶中制备的一种参考抗原和在锥形瓶中制备的五种抗原,我们测试了52种反应性血清和54种非反应性血清。所有血清样品的结果均具有可比性。我们还测试了两批商业抗原和另一批参考抗原。同样,抗原的反应性没有差异。因此,我们得出结论,在制造VDRL抗原时,可以使用25毫升玻璃塞子锥形瓶作为玻璃塞子,平底圆形玻璃瓶的合适替代品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号