首页> 美国卫生研究院文献>AAPS PharmSciTech >Commerical reference shape standards use in the study of particle shape effect on laser diffraction particle size analysis
【2h】

Commerical reference shape standards use in the study of particle shape effect on laser diffraction particle size analysis

机译:商业参考形状标准用于研究激光衍射粒度分析中的颗粒形状效应

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of this paper is to describe the use of LGC Promochem AEA 1001 to AEA 1003 monosized fiberanalog shape standards in the study of the effect of particle shape on laser diffraction (LD) particle size analysis (psa). The psa of the AEA standards was conducted using LD psa systems from Beckman Coulter, Horiba, and Malvern Instruments. Flow speed settings, sample refractive index values, and sample cell types were varied to examine the extent to which the shape effect on LD psa results is modified by these variables. The volume and number probability plots resulting from these measurements were each characterized by a spread in the particle size distribution that roughly extended from the breadth to the longest dimension of the particles. For most of the selected sample refractive index values, the volume probability plots were characterized by apparent bimodal distributions. The results, therefore, provide experimental verification of the conclusions from theoretical studies of LD psa system response to monosized elliptical particles in which this apparent bimodality was the predicted result in the case of flow-oriented particles. The data support the findings from previous studies conducted over the past 10 years that have called into question the verity of the tenets of, and therefore the value of the application of, the equivalent spherical volume diameter theory and the random particle orientation model to the interpretation of LD psa results from measurements made on nonspherical particles.
机译:本文的目的是描述在研究粒子形状对激光衍射(LD)粒度分析(psa)的影响时,使用LGC Promochem AEA 1001至AEA 1003单尺寸纤维模拟形状标准品的方法。 AEA标准的psa使用Beckman Coulter,Horiba和Malvern Instruments的LD psa系统进行。改变流速设置,样品折射率值和样品池类型,以检查这些变量对LD psa结果的形状效应的影响程度。这些测量结果得出的体积和数量概率图分别以粒径分布的分布为特征,该分布从粒径的宽度粗略延伸到最长的尺寸。对于大多数选定的样品折射率值,其体积概率图由表观双峰分布表征。因此,这些结果为LD psa系统对单一尺寸椭圆形颗粒的响应进行理论研究的结论提供了实验验证,其中,这种明显的双峰态是流动取向颗粒情况下的预测结果。数据支持了过去十年中进行的先前研究得出的结论,这些发现使人们对等效球体体积直径理论和随机粒子取向模型的解释的正确性及其应用价值产生疑问。 LD psa的测量结果来自对非球形颗粒的测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号