首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Note: Comparison of the QUANTIPLEX HIV-1 RNA 2.0 Assay with the AMPLICOR HIV-1 MONITOR 1.0 Assay for Quantitation of Levels of Human Immunodeficiency Virus Type 1 RNA in Plasma of Patients Receiving Stavudine-Didanosine Combination Therapy
【2h】

Note: Comparison of the QUANTIPLEX HIV-1 RNA 2.0 Assay with the AMPLICOR HIV-1 MONITOR 1.0 Assay for Quantitation of Levels of Human Immunodeficiency Virus Type 1 RNA in Plasma of Patients Receiving Stavudine-Didanosine Combination Therapy

机译:注意:QUANTIPLEX HIV-1 RNA 2.0分析法与AMPLICOR HIV-1 MONITOR 1.0分析法在定量接受Stavudine-Didanosine联合治疗的患者血浆中人类免疫缺陷病毒1型RNA水平的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We compared the QUANTIPLEX HIV-1 RNA 2.0 assay with the AMPLICOR HIV-1 MONITOR 1.0 assay for quantitation of human immunodeficiency virus type 1 (HIV-1) RNA in plasma in the Stadi trail, which evaluated a stavudine plus didanosine combination therapy in 52 patients. HIV-1 RNA baseline values measured with AMPLICOR HIV-1 MONITOR 1.0 were significantly higher than those measured with QUANTIPLEX HIV-1 RNA 2.0, and decreases in HIV-1 RNA levels from baseline were also found to be significantly higher when measured with the AMPLICOR HIV-1 MONITOR 1.0 assay. The frequency of HIV-1 RNA levels below the lower limit of quantitation was significantly higher with QUANTIPLEX HIV-1 RNA 2.0 than with AMPLICOR HIV-1 MONITOR 1.0. Reanalysis of these results by an ultrasensitive procedure of AMPLICOR HIV-1 MONITOR 1.0 or by a modified version of the test that included additional primers adapted for non-B HIV-1 clades yielded greater differences between the QUANTIPLEX HIV-1 RNA 2.0 assay and the AMPLICOR HIV-1 MONITOR 1.0 assay. Our results indicate that a valid comparison of the virological efficacies obtained with different antiretroviral drug regimens requires the use of the same viral load quantitation procedure; further standardization between the different HIV-1 RNA quantitation kits is therefore needed.
机译:我们比较了QUANTIPLEX HIV-1 RNA 2.0测定法和AMPLICOR HIV-1 MONITOR 1.0测定法在Stadi试验中血浆中人类免疫缺陷病毒1型(HIV-1)RNA定量的方法,该方法在52种药物中评估了司他夫定加二羟肌苷的联合治疗耐心。使用AMPLICOR HIV-1 MONITOR 1.0测得的HIV-1 RNA基线值明显高于使用QUANTIPLEX HIV-1 RNA 2.0测得的HIV-1 RNA基线值,使用AMPLICOR测得的HIV-1 RNA水平也较基线降低。 HIV-1 MONITOR 1.0检测。在QUANTIPLEX HIV-1 RNA 2.0中,低于定量下限的HIV-1 RNA水平频率明显高于在AMPLICOR HIV-1 MONITOR 1.0中。通过AMPLICOR HIV-1 MONITOR 1.0的超灵敏程序或测试的修改版本对这些结果进行重新分析,其中包括适用于非B HIV-1进化枝的其他引物,在QUANTIPLEX HIV-1 RNA 2.0分析法与AMPLICOR HIV-1 MONITOR 1.0检测。我们的结果表明,使用不同的抗逆转录病毒药物方案获得的病毒学功效的有效比较需要使用相同的病毒载量定量程序。因此,需要在不同的HIV-1 RNA定量试剂盒之间进行进一步的标准化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号