首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Comparison of radioimmunoassay and enzyme immunoassay kits for detection of Legionella pneumophila serogroup 1 antigen in both concentrated and nonconcentrated urine samples.
【2h】

Comparison of radioimmunoassay and enzyme immunoassay kits for detection of Legionella pneumophila serogroup 1 antigen in both concentrated and nonconcentrated urine samples.

机译:在浓缩和非浓缩尿液样品中检测肺炎军团菌血清群1抗原的放射免疫分析试剂盒和酶免疫分析试剂盒的比较。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We evaluated a commercial enzyme immunoassay (EIA) kit for detection of Legionella pneumophila serogroup 1 soluble antigen by comparing it to radioimmunoassay (RIA), using both concentrated and nonconcentrated urine samples. The sensitivity of EIA was 67.4% in nonconcentrated urine samples and 82.6% in concentrated urine samples. The sensitivity of RIA was 60.9% and 84.8% in nonconcentrated and concentrated urine samples, respectively. Our study indicates that the sensitivity and specificity of EIA are comparable to those of RIA, and that concentrating the antigen by selective ultrafiltration increases sensitivity for both EIA and RIA, with no significant decrease in specificity.
机译:我们通过使用浓缩和非浓缩尿液样品将其与放射免疫分析(RIA)进行比较,评估了用于检测嗜肺军团杆菌血清群1可溶性抗原的商业酶免疫分析(EIA)试剂盒。在非浓缩尿液样品中,EIA的敏感性为67.4%,在浓缩尿液样品中为82.6%。在未浓缩和浓缩尿液样品中,RIA的敏感性分别为60.9%和84.8%。我们的研究表明,EIA的敏感性和特异性与RIA相当,并且通过选择性超滤浓缩抗原可以提高EIA和RIA的敏感性,而特异性没有明显降低。