The new Multi-View Reconstruction (MVR) method for generating 3D vascular images was evaluated experimentally. The MVR method requires only a few digital subtraction angiographic (DSA) projections to reconstruct the 3D model of the vessel object compared to 180 or more projections for standard CBCT. Full micro-CBCT datasets of a contrast filled carotid vessel phantom were obtained using a Microangiography (MA) detector. From these datasets, a few projections were selected for use in the MVR technique. Similar projection views were also obtained using a standard x-ray image intensifier (II) system. A comparison of the 2D views of the MVRs (MA and II derived) with reference micro-CBCT data, demonstrated best agreement with the MA MVRs, especially at the curved part of the phantom. Additionally, the full 3D MVRs were compared with the full micro-CBCT 3D reconstruction resulting for the phantom with the smallest diameter (0.75 mm) vessel, in a mean centerline deviation from the micro-CBCT derived reconstructions of 29 μm for the MA MVR and 48 μm for the II MVR. The comparison implies that an MVR may be substituted for a full micro-CBCT scan for evaluating vessel segments with consequent substantial savings in patient exposure and contrast media injection yet without substantial loss in 3D image content. If a high resolution system with MA detector is used, the improved resolution could be well suited for endovascular image guided interventions where visualization of only a small field of view (FOV) is required.
机译:实验评估了用于生成3D血管图像的新的多视图重建(MVR)方法。与标准CBCT的180个或更多投影相比,MVR方法仅需要几个数字减影血管造影(DSA)投影即可重建血管对象的3D模型。使用微血管造影(MA)检测器获得对比填充的颈动脉体模的完整micro-CBCT数据集。从这些数据集中,选择了一些投影用于MVR技术。使用标准X射线图像增强器(II)系统也可以获得类似的投影视图。 MVR(从MA和II衍生)的2D视图与参考micro-CBCT数据的比较表明,与MA MVR的一致性最佳,尤其是在体模的弯曲部分。此外,将完整的3D MVR与完整的微型CBCT 3D重建物(直径最小的血管(0.75毫米)比较)进行了比较,与从M-CBCT衍生的重建的29μm的平均中心线偏差相比,MA MVR和II MVR为48μm。比较表明,可以用MVR代替完整的micro-CBCT扫描来评估血管段,从而在节省患者暴露和造影剂注射方面节省大量资金,却不会在3D图像内容上造成重大损失。如果使用带有MA检测器的高分辨率系统,则改进后的分辨率可能非常适合需要可视化小视野(FOV)的血管内图像引导介入治疗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号