首页> 美国卫生研究院文献>other >Determination of Coenzyme Q10 Content in Raw Materials and Dietary Supplements by High-Performance Liquid Chromatography-UV: Collaborative Study
【2h】

Determination of Coenzyme Q10 Content in Raw Materials and Dietary Supplements by High-Performance Liquid Chromatography-UV: Collaborative Study

机译:高效液相色谱-紫外光谱法测定原料和膳食补充剂中辅酶Q10含量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

An international collaborative study was conducted of a high-performance liquid chromatographic (HPLC)-UV method for the determination of coenzyme Q10 (CoQ10, ubidecarenone) in raw materials and dietary supplements. Ten collaborating laboratories determined the total CoQ10 content in 8 blind duplicate samples. Sample materials included CoQ10 raw material and 4 finished product dietary supplements representing softgels, hardshell gelatin capsules, and chewable wafers. In addition, collaborating laboratories received a negative control and negative control spiked with CoQ10 at low and high levels to determine recovery. Materials were extracted with an acetonitrile–tetrahydrofuran–water mixture. Ferric chloride was added to the test solutions to ensure all CoQ10 was in the oxidized form. The HPLC analyses were performed on a C18 column using UV detection at 275 nm. Repeatability relative standard deviations (RSDr) ranged from 0.94 to 5.05%. Reproducibility relative standard deviations (RSDR) ranged from 3.08 to 17.1%, with HorRat values ranging from 1.26 to 5.17. Recoveries ranged from 74.0 to 115%. Based on these results, the method is recommended for Official First Action for determination of CoQ10 in raw materials and dietary supplement finished products containing CoQ10 at a concentration of >100 mg CoQ10/g test material.
机译:进行了一项国际合作研究,该研究涉及一种高效液相色谱(HPLC)-UV方法,用于测定原材料和膳食补充剂中的辅酶Q10(辅酶Q10,泛癸烯酮)。十个合作实验室确定了8个盲重复样品中的总CoQ10含量。样品材料包括辅酶Q10原材料和4种制成品的膳食补充剂,分别代表软胶囊,硬壳明胶胶囊和可咀嚼的威化饼。此外,合作实验室还接受了阴性对照和添加了辅酶Q10的阴性对照,以测定其回收率的高低。用乙腈-四氢呋喃-水混合物萃取物料。将氯化铁添加到测试溶液中,以确保所有的辅酶Q10均为氧化形式。 HPLC分析在C18柱上使用275nm的UV检测进行。重复性相对标准偏差(RSDr)为0.94至5.05%。重现性相对标准偏差(RSDR)为3.08%至17.1%,HorRat值为1.26至5.17。回收率从74.0到115%。根据这些结果,建议将该方法用于《官方第一个行动》中测定含量大于100 mg CoQ10 / g的辅酶Q10的原料和膳食补充剂成品中的辅酶Q10的方法。

著录项

  • 期刊名称 other
  • 作者

    Steven Lunetta; Mark Roman;

  • 作者单位
  • 年(卷),期 -1(91),4
  • 年度 -1
  • 页码 702–708
  • 总页数 18
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号