摘要

Modified procedures for the Sceptor Gram-Positive MIC Panel and the Vitek AutoMicrobic System GPS-M Card were evaluated for their ability to detect methicillin-resistant (heteroresistant) Staphylococcus aureus. A total of 398 clinical isolates (including 222 methicillin-resistant S. aureus) obtained from 10 hospitals were tested. Both systems had 2% NaCl in the oxacillin wells. Sceptor MIC panels were inoculated with an organism suspension prepared from an 18- to 24-h blood agar plate and were inoculated for a full 24 h at 35 degrees C before MICs were read. All methicillin-resistant S. aureus isolates were detected as resistant to oxacillin at greater than or equal to 8 micrograms/ml by the Sceptor method and at greater than 2 micrograms/ml by the Vitek method. All 176 oxacillin-susceptible, methicillin-susceptible S. aureus isolates were correctly distinguished from methicillin-resistant S. aureus isolates by Sceptor. However, with the Vitek system 29 methicillin-susceptible S. aureus isolates tested as falsely resistant to oxacillin and four isolates tested as falsely resistant to vancomycin. The modified testing procedure with the Sceptor system can be used reliably for accurate susceptibility testing of methicillin-resistant and methicillin-susceptible S. aureus. The Vitek GPS-M card does not accurately discriminate between methicillin-resistant and methicillin-susceptible S. aureus with an oxacillin breakpoint of greater than 2 micrograms/ml.
机译:对Sceptor革兰氏阳性MIC面板和Vitek AutoMicrobic System GPS-M卡的修改程序进行了评估,以检测其对耐甲氧西林(杂合)金黄色葡萄球菌的能力。测试了从10家医院获得的398株临床分离株(包括222株耐甲氧西林金黄色葡萄球菌)。两种系统在奥沙西林孔中均含有2%NaCl。用从18到24小时的血琼脂平板制备的生物悬浮液接种Sceptor MIC板,并在读取MIC之前在35摄氏度下接种24小时。通过Sceptor方法检测到所有耐甲氧西林的金黄色葡萄球菌对奥沙西林的耐药性均大于或等于8微克/毫升,通过Vitek方法检出对奥沙西林的耐药性大于2微克/毫升。通过Sceptor可以正确区分所有176份对奥沙西林敏感的,对甲氧西林敏感的金黄色葡萄球菌分离株与耐甲氧西林的金黄色葡萄球菌分离株。但是,在Vitek系统中,对甲氧西林敏感的金黄色葡萄球菌29种分离物经测试对oxacillin有错误的抵抗力,对4种分离物对万古霉素有错误的抵抗力。使用Sceptor系统改进的测试程序可以可靠地用于耐甲氧西林和对甲氧西林敏感的金黄色葡萄球菌的准确药敏试验。 Vitek GPS-M卡无法准确区分耐甲氧西林和易感甲氧西林的金黄色葡萄球菌,其奥沙西林断点大于2微克/毫升。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号