Minimizing Superficial Thermal Injury Using Bilateral Cryogen Spray Cooling During Laser Reshaping of Composite Cartilage Grafts

机译:在复合软骨移植物的激光整形过程中使用双侧冷剂喷雾冷却将表面热损伤降至最低

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Composite cartilage grafts were excised from New Zealand rabbit ears. Flat composite grafts (of cartilage and overlying skin graft on both surfaces) were obtained from each ear and cut into a rectangle measuring 50 mm by 25 mm (x by y) with an average thickness of approximately 1.3 mm (z), skin included. Specimens were manually deformed with a jig and maintained in this new position during laser illumination. The composite cartilage grafts were illuminated on the concave surface with an Nd:YAG laser (1,064 nm, 3 mm spot) at 10 W, 20 W, 30 W, 40 W, 50 W. Cryogen spray cooling (CSC) was applied to both exterior (convex) and interior (concave) surfaces of the tissue to reduce thermal injury to the grafts. CSC was delivered: (1) in controlled applications (cryogen released when surface reached 40°C, and (2) receiving only laser at above wattage, no CSC [representing the control group]. The specimens were maintained in a deformation for 15 minutes after illumination and serially examined for 14 days. The control group with no CSC caused injury to all specimens, ranging from minor to full thickness epidermal thermal injury. Although most levels of laser and CSC yielded a high degree of reshaping over an acute time period, after 14 days specimens exposed to 30 W, 40 W, 50 W retained shape better than those treated at 10 W and 20 W. The specimens exposed to 50 W with controlled CSC retained its new shape to the highest degree over all others, and thermal injury was minimal. In conclusion, combinations of laser and CSC parameters were effective and practical for the reshaping of composite cartilage grafts. Lasers Surg.
机译:从新西兰兔耳朵切下复合软骨移植物。从每只耳朵获得扁平的复合材料移植物(在两个表面上均具有软骨和上覆的皮肤移植物),并切成50mm x 25 mm(x x y)的矩形,平均厚度约为1.3 mm(z),包括皮肤。样品用夹具手动变形,并在激光照射过程中保持在这个新位置。用Nd:YAG激光(1,064 nm,3 mm点)在10 W,20 W,30 W,40 W,50 W的凹表面上照亮复合软骨移植物。对两者均施以低温喷雾冷却(CSC)组织的外(凸)面和内(凹)面,以减少对移植物的热损伤。提供了CSC:(1)在受控的应用中(当表面温度达到40°C时,低温释放;并且(2)仅接受功率高于瓦特的激光,没有CSC [代表对照组]。将样品保持变形15分钟)光照后连续检查14天,无CSC的对照组对所有标本均造成了损伤,范围从轻度到全厚度的表皮热损伤,尽管大多数水平的激光和CSC在急性期内产生了高度的整形, 14天后,暴露于30 W,40 W,50 W的样品保持的形状优于10 W和20 W处理的样品。在受控CSC的情况下暴露于50 W的样品,其形状保持最高,高于其他所有样品。总之,激光和CSC参数的组合对于复合软骨移植物的整形是有效和实用的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号