Adherence of coagulase-negative staphylococci to plastic tissue culture plates: a quantitative model for the adherence of staphylococci to medical devices.

机译:凝固酶阴性葡萄球菌对塑料组织培养板的粘附:葡萄球菌对医疗器械粘附的定量模型。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The adherence of coagulase-negative staphylococci to smooth surfaces was assayed by measuring the optical densities of stained bacterial films adherent to the floors of plastic tissue culture plates. The optical densities correlated with the weight of the adherent bacterial film (r = 0.906; P less than 0.01). The measurements also agreed with visual assessments of bacterial adherence to culture tubes, microtiter plates, and tissue culture plates. Selected clinical strains were passed through a mouse model for foreign body infections and a rat model for catheter-induced endocarditis. The adherence measurements of animal passed strains remained the same as those of the laboratory-maintained parent strain. Spectrophotometric classification of coagulase-negative staphylococci into nonadherent and adherent categories according to these measurements had a sensitivity, specificity, and accuracy of 90.6, 80.8, and 88.4%, respectively. We examined a previously described collection of 127 strains of coagulase-negative staphylococci isolated from an outbreak of intravascular catheter-associated sepsis; strains associated with sepsis were more adherent than blood culture contaminants and cutaneous strains (P less than 0.001). We also examined a collection of 84 strains isolated from pediatric patients with cerebrospinal fluid (CSF) shunts; once again, pathogenic strains were more adherent than were CSF contaminants (P less than 0.01). Finally, we measured the adherence of seven endocarditis strains. As opposed to strains associated with intravascular catheters and CSF shunts, endocarditis strains were less adherent than were saprophytic strains of coagulase-negative staphylococci. The optical densities of bacterial films adherent to plastic tissue culture plates serve as a quantitative model for the study of the adherence of coagulase-negative staphylococci to medical devices, a process which may be important in the pathogenesis of foreign body infections.
机译:凝固酶阴性葡萄球菌对光滑表面的粘附力是通过测量粘附在塑料组织培养板上的细菌膜的光密度来测定的。光学密度与粘附细菌膜的重量相关(r = 0.906; P小于0.01)。测量结果还与目测评估细菌对培养管,微量滴定板和组织培养板的粘附性相吻合。选定的临床菌株通过异物感染的小鼠模型和导管诱发的心内膜炎的大鼠模型。动物传代菌株的依从性测量结果与实验室维持的亲本菌株的依从性测量结果相同。根据这些测量结果,将凝固酶阴性葡萄球菌分光光度分类为非粘附和粘附类别,其灵敏度,特异性和准确度分别为90.6%,80.8和88.4%。我们检查了先前描述的从与血管内导管相关的脓毒症暴发中分离出来的127株凝固酶阴性葡萄球菌菌株的集合;与败血症相关的菌株比血液培养物污染物和皮肤菌株更具粘附性(P小于0.001)。我们还检查了从脑脊液(CSF)分流患儿中分离出的84株菌株。再次,致病菌株比CSF污染物更具粘附性(P小于0.01)。最后,我们测量了七种心内膜炎菌株的依从性。与与血管内导管和CSF分流器相关的菌株相反,与凝固酶阴性葡萄球菌的腐生菌株相比,心内膜炎菌株的黏附性较低。粘附在塑料组织培养板上的细菌膜的光密度可作为定量模型,用于研究凝固酶阴性葡萄球菌对医疗器械的粘附,该过程在异物感染的发病机理中可能很重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号