A comparison of the validity of downloadable motion sensors, which use either a glass-enclosed magnetic reed proximity switch technology, a piezo-electric sensor accelerometer with a horizontal beam technology, or an internal pendulum based mechanism to determine energy expenditure (EE), across different body sizes does not exist. Therefore, the purpose of this study was to determine the validity of three different downloadable motion sensors to estimate EE during walking activity in normal weight, overweight and obese volunteers. Forty-eight participants completed this study. Each participant had their body height and mass measured and completed a treadmill walking protocol. Body mass index (BMI) was calculated. The treadmill walking protocol included six 5-minute stages starting at 1.5 mph and increasing by 0.5 mph, up to 4.0 mph while grade was constant at 0% for the duration of the test. The Kenz Life-Corder EX (LC), the Omron HJ-700IT (OM) and the Sportbrain iStep X1 (SB) were worn during the treadmill walking protocol. Heart rate, oxygen consumption, carbon dioxide production and EE estimated from the motion sensors were monitored throughout the walking protocol. Results showed the OM overestimated net EE in normal, overweight and obese participants. The LC underestimated gross EE in all groups. The SB overestimated net EE in normal BMI participants, was not significantly different from the criterion measure of net EE in overweight participants and underestimated net EE in obese individuals. This study demonstrates that these devices do not offer the accuracy needed to provide precise feedback on EE for individuals with varying BMI levels.
机译:可下载运动传感器的有效性比较,该传感器使用玻璃封闭的磁簧接近开关技术,具有水平射束技术的压电传感器加速度计或基于内部摆锤的机构来确定能量消耗(EE)不存在不同的体型。因此,本研究的目的是确定三种不同的可下载运动传感器在正常体重,超重和肥胖志愿者步行活动期间估算EE的有效性。四十八名参与者完成了这项研究。测量每个参与者的身高和体重,并完成跑步机步行方案。计算体重指数(BMI)。跑步机步行方案包括六个5分钟的阶段,从1.5 mph开始,以0.5 mph的速度增加,直至4.0 mph,而在测试期间,坡度恒定为0%。在跑步机步行过程中,佩戴了Kenz Life-Corder EX(LC),Omron HJ-700IT(OM)和Sportbrain iStep X1(SB)。在整个步行方案中,均会监测运动传感器估算出的心率,氧气消耗量,二氧化碳生成量和EE。结果显示,正常,超重和肥胖参与者的OM高估了净EE。 LC低估了所有组中的EE总值。正常BMI参与者的SB高估了净EE,与超重参与者的净EE的标准测度和肥胖个体的净EE的低估没有显着差异。这项研究表明,这些设备无法提供为BMI水平各不相同的人提供有关EE的精确反馈所需的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号