首页> 美国卫生研究院文献>other >Estimation of Cardiac Respiratory-Motion by Semi-Automatic Segmentation and Registration of Non-Contrast-Enhanced 4D-CT Cardiac Datasets
【2h】

Estimation of Cardiac Respiratory-Motion by Semi-Automatic Segmentation and Registration of Non-Contrast-Enhanced 4D-CT Cardiac Datasets

机译:心脏呼吸运动的半自动分割的估计和非对比增强4D-CT心脏数据集的登记

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The goal of this work is to investigate, for a large set of patients, the motion of the heart with respiration during free-breathing supine medical imaging. For this purpose we analyzed the motion of the heart in 32 non-contrast enhanced respiratory-gated 4D-CT datasets acquired during quiet unconstrained breathing. The respiratory-gated CT images covered the cardiac region and were acquired at each of 10 stages of the respiratory cycle, with the first stage being end-inspiration. We devised a 3-D semi-automated segmentation algorithm that segments the heart in the 4D-CT datasets acquired without contrast enhancement for use in estimating respiratory motion of the heart. Our semi-automated segmentation results were compared against interactive hand segmentations of the coronal slices by a cardiologist and a radiologist. The pairwise difference in segmentation among the algorithm and the physicians was on the average 11% and 10% of the total average segmented volume across the patient, with a couple of patients as outliers above the 95% agreement limit. The mean difference among the two physicians was 8% with an outlier above the 95% agreement limit. The 3-D segmentation was an order of magnitude faster than the Physicians’ manual segmentation and represents significant reduction of Physicians’ time. The segmented first stages of respiration were used in 12 degree-of-freedom (DOF) affine registration to estimate the motion at each subsequent stage of respiration. The registration results from the 32 patients indicate that the translation in the superior-inferior direction was the largest component motion, with a maximum of 10.7 mm, mean of 6.4 mm, and standard deviation of 2.2 mm. Translation in the anterior-posterior direction was the next largest component of motion, with a maximum of 4.0 mm, mean of 1.7 mm, and standard deviation of 1.0 mm. Rotation about the right-left axis was on average the largest component of rotation observed, with a maximum of 4.6 degrees, mean of 1.6 degrees, and standard deviation of 2.1 degrees. The other rotation and shear parameters were all close to zero on average indicting the motion could be reasonably well approximated by rigid-body motion. However, the product of the three scale factors averaged about 0.97 indicating the possibility of a small decrease in heart volume with expiration. The motion results were similar whether we used the Physician’s segmentation or the 3-D algorithm.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号