Automated gray matter segmentation of magnetic resonance imaging data is essential for morphometric analyses of the brain, particularly when large sample sizes are investigated. However, although detection of small structural brain differences may fundamentally depend on the method used, both accuracy and reliability of different automated segmentation algorithms have rarely been compared. Here, performance of the segmentation algorithms provided by SPM8, VBM8, FSL and FreeSurfer was quantified on simulated and real magnetic resonance imaging data. First, accuracy was assessed by comparing segmentations of twenty simulated and 18 real T1 images with corresponding ground truth images. Second, reliability was determined in ten T1 images from the same subject and in ten T1 images of different subjects scanned twice. Third, the impact of preprocessing steps on segmentation accuracy was investigated. VBM8 showed a very high accuracy and a very high reliability. FSL achieved the highest accuracy but demonstrated poor reliability and FreeSurfer showed the lowest accuracy, but high reliability. An universally valid recommendation on how to implement morphometric analyses is not warranted due to the vast number of scanning and analysis parameters. However, our analysis suggests that researchers can optimize their individual processing procedures with respect to final segmentation quality and exemplifies adequate performance criteria.
机译:磁共振成像数据的自动灰质分割对于大脑的形态分析至关重要,特别是在研究了大样本量时。但是,尽管检测到小的大脑结构差异可能从根本上取决于所使用的方法,但是很少会比较不同自动分割算法的准确性和可靠性。在这里,由SPM8,VBM8,FSL和FreeSurfer提供的分割算法的性能在模拟和真实的磁共振成像数据上进行了量化。首先,通过将二十个模拟和18个真实T1图像的分割与相应的地面真实图像进行比较来评估准确性。其次,确定了来自同一对象的十张T1图像和两次扫描的不同对象的十张T1图像的可靠性。第三,研究了预处理步骤对分割精度的影响。 VBM8显示出非常高的精度和非常高的可靠性。 FSL获得了最高的准确度,但显示出较差的可靠性,而FreeSurfer显示出最低的准确度,但具有高可靠性。由于存在大量的扫描和分析参数,因此不保证有关如何进行形态计量分析的通用建议。但是,我们的分析表明,研究人员可以针对最终分割质量优化各自的处理程序,并举例说明适当的性能标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号