首页> 美国卫生研究院文献>other >Real-Time Continuous Glucose Monitoring Shows High Accuracy within 6 Hours after Sensor Calibration: A Prospective Study
【2h】

Real-Time Continuous Glucose Monitoring Shows High Accuracy within 6 Hours after Sensor Calibration: A Prospective Study

机译:实时连续葡萄糖监测显示传感器校准后6小时内的高精度:一项前瞻性研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Accurate and timely glucose monitoring is essential in intensive care units. Real-time continuous glucose monitoring system (CGMS) has been advocated for many years to improve glycemic management in critically ill patients. In order to determine the effect of calibration time on the accuracy of CGMS, real-time subcutaneous CGMS was used in 18 critically ill patients. CGMS sensor was calibrated with blood glucose measurements by blood gas/glucose analyzer every 12 hours. Venous blood was sampled every 2 to 4 hours, and glucose concentration was measured by standard central laboratory device (CLD) and by blood gas/glucose analyzer. With CLD measurement as reference, relative absolute difference (mean±SD) in CGMS and blood gas/glucose analyzer were 14.4%±12.2% and 6.5%±6.2%, respectively. The percentage of matched points in Clarke error grid zone A was 74.8% in CGMS, and 98.4% in blood gas/glucose analyzer. The relative absolute difference of CGMS obtained within 6 hours after sensor calibration (8.8%±7.2%) was significantly less than that between 6 to 12 hours after calibration (20.1%±13.5%, p<0.0001). The percentage of matched points in Clarke error grid zone A was also significantly higher in data sets within 6 hours after calibration (92.4% versus 57.1%, p<0.0001). In conclusion, real-time subcutaneous CGMS is accurate in glucose monitoring in critically ill patients. CGMS sensor should be calibrated less than 6 hours, no matter what time interval recommended by manufacturer.
机译:在重症监护病房中,准确及时的血糖监测至关重要。多年来,一直提倡使用实时连续葡萄糖监测系统(CGMS)来改善危重患者的血糖管理。为了确定校准时间对CGMS准确性的影响,在18名危重患者中使用了实时皮下CGMS。每12小时用血气/葡萄糖分析仪的血糖测量值校准CGMS传感器。每2至4小时取样一次静脉血,并通过标准中央实验室设备(CLD)和血气/葡萄糖分析仪测量葡萄糖浓度。以CLD测量为参考,CGMS和血气/葡萄糖分析仪的相对绝对差(mean±SD)分别为14.4%±12.2%和6.5%±6.2%。在CGMS中,克拉克误差网格区域A中的匹配点百分比为74.8%,在血气/葡萄糖分析仪中为98.4%。传感器校准后6小时内获得的CGMS的相对绝对差(8.8%±7.2%)明显小于传感器校准后6至12小时之间的CGMS的相对绝对差(20.1%±13.5%,p <0.0001)。校准后6小时内,数据集中的Clarke误差网格区域A中的匹配点百分比也显着较高(92.4%对57.1%,p <0.0001)。总而言之,实时皮下CGMS在危重患者的血糖监测中是准确的。 CGMS传感器应校准少于6小时,无论制造商建议的时间间隔如何。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号