首页> 美国卫生研究院文献>other >Determination of PCDD/Fs PBDD/Fs and dioxin-like PCBs in human milk from mothers residing in the rural areas in Flanders using the CALUX bioassay and GC-HRMS
【2h】

Determination of PCDD/Fs PBDD/Fs and dioxin-like PCBs in human milk from mothers residing in the rural areas in Flanders using the CALUX bioassay and GC-HRMS

机译:使用CALUX生物测定法和GC-HRMS法测定富兰德农村地区母亲的母乳中PCDD / FsPBDD / Fs和二恶英样PCB

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Since the CALUX (Chemically Activated LUciferase gene eXpression) bioassay is a fast and inexpensive tool for the determination of dioxin-like compounds in a large number of samples and requires only small sample volumes, the use of this technique in human biomonitoring programs provides a good alternative to GC-HRMS. In this study, a new CALUX method for the separate analysis of PCDD/Fs and dioxin-like PCBs (dl-PCBs) in small amounts of human milk samples with the new sensitive H1L7.5c1 cell line was used to analyze 84 human milk samples, collected from mothers residing in the Flemish rural communities. The geometric mean CALUX-Bioanalytical Equivalent (CALUX-BEQ) values, reported for the 84 mothers from the study area were 10.4 (95% CI: 9.4–11.4) pg CALUX-BEQ per g lipid or 0.41 (95% CI: 0.37–0.45) pg CALUX-BEQ per g milk for the PCDD/Fs and 1.73 (1.57–1.91) pg CALUX-BEQ per g lipid or 0.07 (95% CI: 0.06–0.08) pg CALUX-BEQ per g milk for the dioxin-like PCBs. Multiple regression analysis showed significant associations between PCDD/Fs and weight change after pregnancy, smoking and consumption of local eggs. One pooled human milk sample was analyzed with both CALUX and GC-HRMS. The ratio of CALUX and GC-HRMS results for this sample were respectively 1.60, 0.58 and 1.23 for the PCDD/Fs, the dl-PCBs and the sum of both fractions, when using the 2005-TEF values. Additionally, also low levels of certain brominated dioxins and furans were detected in the pooled sample with GC-HRMS.
机译:由于CALUX(化学活化的荧光素酶基因表达)生物测定是一种用于测定大量样品中二恶英类化合物的快速且廉价的工具,并且仅需少量样品即可,因此在人类生物监测程序中使用此技术提供了一个很好的方法替代GC-HRMS。在这项研究中,采用新的CALUX方法,使用新的敏感H1L7.5c1细胞系,分别分析少量人乳样品中的PCDD / Fs和二恶英样PCB(dl-PCBs),用于分析84种人乳样品收集自佛兰芒乡村社区的母亲。研究区域的84位母亲所报告的几何平均CALUX-生物分析当量(CALUX-BEQ)值是每克脂质10.4(95%CI:9.4-11.4)pg CALUX-BEQ或0.41(95%CI:0.37-对于PCDD / Fs,每克牛奶0.45)pg CALUX-BEQ,每克脂质1.73(1.57–1.91)pg CALUX-BEQ或对于二恶英-每克牛奶0.07(95%CI:0.06-0.08)pg CALUX-BEQ如PCB。多元回归分析显示,妊娠,吸烟和食用局部鸡蛋后体重变化与PCDD / Fs显着相关。用CALUX和GC-HRMS对一份合并的人乳样品进行了分析。当使用2005-TEF值时,对于PCDD / F,dl-PCBs和两个馏分的总和,该样品的CALUX和GC-HRMS结果之比分别为1.60、0.58和1.23。此外,在使用GC-HRMS收集的样品中还检测到少量的某些溴化二恶英和呋喃。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号