Sequence design and evaluation of the reproducibility of water selective diffusion weighted imaging of the breast at 3T

机译:3T乳腺水选择性扩散加权成像的可重复性的序列设计和评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Diffusion measurements derived from breast MRI can be adversely affected by unwanted signals from abundant fatty tissues if they are not suppressed adequately. To minimize this undesired contribution, we design and optimize a water selective DWI sequence, which relies on spectrally selective excitation on the water resonance, obviating the need for fat suppression. As this method is more complex than standard DWI methods, we also report a test-retest study to evaluate its reproducibility. In this study, a spectrally selective Gaussian pulse on water resonance is combined with a pair of slice selective adiabatic refocusing pulses for water only DWI. Field-map based shimming and manual determination of the center frequency are used for water selection. The selectivity of the excitation pulse is optimized by a spectrally selective spectroscopy sequence based on the same principles. A test-retest study of 10 volunteers in two separate visits is used to evaluate its reproducibility. Our results from all subjects show high quality diffusion weighted images of the breast without fat contamination. Mean ADC values for b = 0, 600 s/mm2 and b = 50, 600 s/mm2 all show good reproducibility as 95% confidence intervals (CI) of the apparent diffusion coefficient values are 4×10−5 mm2/s and 5×10−5 mm2/s and repeatability values are 1.09×10−4 and 1.31×10−4, respectively. In conclusion, water selective DWI is a feasible alternative to standard methods of DWI based on fat suppression. The added complexity of the method does not compromise the reproducibility of diffusion measurements in the breast.
机译:如果无法充分抑制,来自丰乳组织的有害信号可能会对源自乳房MRI的扩散测量产生不利影响。为了最大程度地减少这种不希望有的贡献,我们设计并优化了水选择性DWI序列,该序列依赖于水共振的光谱选择性激发,从而消除了对脂肪抑制的需求。由于此方法比标准DWI方法更复杂,因此我们还报告了一项重新测试研究以评估其可重复性。在这项研究中,对水共振的光谱选择性高斯脉冲与一对仅用于水的DWI的切片选择性绝热重聚焦脉冲相结合。基于场图的匀场和手动确定中心频率用于选水。激发脉冲的选择性通过基于相同原理的光谱选择性光谱序列进行优化。在两次单独的访问中对10名志愿者进行了一次测试-再测试研究,以评估其可重复性。我们所有受试者的结果均显示了高质量的乳房扩散扩散加权图像,没有脂肪污染。 b = 0,600 s / mm 2 和b = 50,600 s / mm 2 的ADC均值均显示出良好的重现性,因为95%置信区间(CI)为表观扩散系数值为4×10 -5 mm 2 / s和5×10 -5 mm 2 / s和重复性值分别为1.09×10 −4 和1.31×10 −4 。总之,水选择性DWI是基于脂肪抑制的DWI标准方法的可行替代方法。该方法增加的复杂性不会影响乳房中扩散测量的可重复性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号