首页> 美国卫生研究院文献>other >High-Resolution Ambient MS Imaging of Negative Ions in Positive Ion Mode: Using Dicationic Reagents with the Single-Probe
【2h】

High-Resolution Ambient MS Imaging of Negative Ions in Positive Ion Mode: Using Dicationic Reagents with the Single-Probe

机译:正离子模式下负离子的高分辨率环境MS成像:结合使用带单探针的阳离子试剂

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We have used the Single-probe, a miniaturized sampling device utilizing in-situ surface microextraction for ambient mass spectrometry (MS) analysis, for the high resolution MS imaging (MSI) of negatively charged species in the positive ionization mode. Two dicationic compounds, 1,5-pentanediyl-bis(1-butylpyrrolidinium) difluoride [C5(bpyr)2F2] and 1,3-propanediyl-bis(tripropylphosphonium) difluoride [C3(triprp)2F2], were added into the sampling solvent to form 1+ charged adducts with the negatively charged species extracted from tissues. We were able to detect 526 and 322 negatively charged species this way using [C5(bpyr)2F2] and [C3(triprp)2F2], respectively, including oleic acid, arachidonic acid, and several species of phosphatidic acid, phosphoethanolamine, phosphatidylserine, phosphatidylglycerol, phosphatidylinositol, and others. In conjunction with the identification of the non-adduct cations, we have tentatively identified a total number of 1200 and 828 metabolites from mouse brain sections using [C5(bpyr)2F2] and [C3(triprp)2F2], respectively, through high mass accuracy measurements (mass error <5 ppm); MS/MS analyses were also performed to verify the identity of selected species. In addition to the high mass accuracy measurement, we were able to generate high spatial resolution (~17 µm) MS images of mouse brain sections. Our study demonstrated that utilization of dicationic compounds in the surface microextraction with the Single-probe device can perform high mass and spatial resolution ambient MSI measurements of broader types of compounds in tissues. Other reagents can be potentially used with the Single-probe device for a variety of reactive MSI studies to enable the analysis of species that are previously intractable.
机译:我们已经使用Single-probe(一种微型采样设备),利用原位表面微萃取进行环境质谱(MS)分析,用于在正电离模式下对带负电的物质进行高分辨率MS成像(MSI)。将两种特殊化合物1,5-戊二基-双(1-丁基吡咯烷鎓)二氟化物[C5(bpyr)2F2]和1,3-丙二基-双(三丙基phosph)二氟化物[C3(triprp)2F2]添加到采样溶剂中与从组织中提取的带负电物质形成1+带电加合物。通过使用[C5(bpyr)2F2]和[C3(triprp)2F2],我们能够分别检测到526和322个带负电荷的物质,包括油酸,花生四烯酸和几种磷脂酸,磷酸乙醇胺,磷脂酰丝氨酸,磷脂酰甘油,磷脂酰肌醇等。结合非加成阳离子的鉴定,我们已尝试使用[C5(bpyr)2F2]和[C3(triprp) 2 从小鼠大脑切片中共鉴定出1200和828种代谢物F 2 ],分别通过高质量准确度测量(质量误差<5 ppm)进行;还进行了MS / MS分析,以验证所选物种的身份。除了进行高质量精确度测量外,我们还能够生成小鼠大脑切片的高空间分辨率(〜17 µm)MS图像。我们的研究表明,利用单探针设备在表面微萃取中使用特殊化合物可以对组织中更广泛类型的化合物进行高质量和空间分辨率的环境MSI测量。 Single-probe设备可能会与其他试剂一起用于各种反应性MSI研究,从而能够分析以前难以处理的物种。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号