首页> 美国卫生研究院文献>other >Use of Direct LAMP Screening of Broiler Fecal Samples for Campylobacter jejuni and Campylobacter coli in the Positive Flock Identification Strategy
【2h】

Use of Direct LAMP Screening of Broiler Fecal Samples for Campylobacter jejuni and Campylobacter coli in the Positive Flock Identification Strategy

机译:空肠弯曲菌和大肠弯曲菌肉鸡粪便样品的直接LAMP筛选在阳性鸡群鉴定策略中的应用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Rapid identification of Campylobacter-positive flocks before slaughter, following freezing and heat treatment for the Campylobacter-positive carcasses at the slaughterhouses is an effective control strategy against foodborne campylobacteriosis. We evaluated a loop-mediated isothermal amplification (LAMP) assay for the direct screening of naturally contaminated chicken cloacal swabs for C. jejuni/C. coli to compare this assay with conventional quantitative culture methods. In a comparison study of 165 broilers, the LAMP assay showed 82.8% (48/58 by conventional culture) sensitivity, 100% (107/107) specificity, 100% (48/48) positive predictive value (PPV), and 91.5% (107/117) negative predictive value (NPV). In a comparison of 55 flocks, LAMP showed 90.5% (19/21) sensitivity, 100% (34/34) specificity, 100% (19/19) PPV, and 94.4% (34/36) NPV. In the cumulative total of 28 farm-level comparisons, LAMP showed 100% (12/12) sensitivity, 100% (16/16) specificity, 100% (12/12) PPV, and 100% (16/16) NPV. The LAMP assay required less than 90 min from the arrival of the fecal samples to final results in the laboratory. This suggests that the LAMP assay will facilitate the identification of C. jejuni/C. coli-positive broiler flocks at the farm level or in slaughterhouses before slaughtering, which would make it an effective tool in preventing the spread of Campylobacter contamination.
机译:在屠宰场对弯曲杆菌阳性屠体进行冷冻和热处理后,在宰杀之前快速鉴定弯曲杆菌阳性鸡群是一种有效的控制食源性弯曲杆菌病的策略。我们评估了一种环介导的等温扩增(LAMP)分析方法,用于直接筛选天然污染的鸡泄殖腔拭子中的空肠弯曲杆菌/ C。大肠杆菌以将该测定与常规定量培养方法进行比较。在对165个肉鸡的比较研究中,LAMP分析显示出82.8%(常规培养为48/58)敏感性,100%(107/107)特异性,100%(48/48)阳性预测值(PPV)和91.5% (107/117)阴性预测值(NPV)。在比较55个鸡群时,LAMP显示90.5%(19/21)敏感性,100%(34/34)特异性,100%(19/19)PPV和94.4%(34/36)NPV。在总计28个农场水平比较中,LAMP显示出100%(12/12)敏感性,100%(16/16)特异性,100%(12/12)PPV和100%(16/16)NPV。从粪便样本到达实验室到最终结果,LAMP分析所需的时间不到90分钟。这表明LAMP测定法将有助于鉴定空肠弯曲杆菌/ C。屠宰前在农场一级或屠宰场中的大肠杆菌阳性肉鸡群,将使其成为防止弯曲杆菌污染扩散的有效工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号