In this study, we examined the repeatability of computed tomography (CT) lung volume measurements in healthy individuals and patients with obstructive and restrictive lung diseases. To do this, we retrospectively enrolled 200 healthy individuals (group 1), 100 patients with obstructive lung disease (group 2), and 100 patients with restrictive lung disease (group 3) who underwent two consecutive chest CT scans within a 1-year period. The CT lung volume was measured using a threshold-based, three-dimensional auto-segmentation technique at a default range from –200 to –1024 HU. The within-subject standard deviation, repeatability coefficient, within-subject coefficient variability, and intraclass correlation coefficient were evaluated. No significant differences were identified between the two consecutive CT lung volume measurements in any of the groups (p> 0.05). The within-subject standard deviations for groups 1, 2, and 3 were 441.1, 387.0, and 288.6, respectively, while the repeatability coefficients were 1222.6, 1072.6, and 800.1, respectively. The within-subject coefficient variabilities for groups 1, 2, and 3 were 0.097, 0.083, and 0.090, respectively, while the intraclass correlation coefficients were 0.818, 0.881, and 0.910, respectively. The two CT lung volume measurements showed excellent agreement in healthy individuals and patients with obstructive or restrictive lung disease. However, the repeatability was lower in healthy individuals than it was in patients with lung diseases.
机译:在这项研究中,我们检查了健康个体和阻塞性和限制性肺疾病患者的计算机断层扫描(CT)肺容积测量的可重复性。为此,我们回顾性纳入了200名健康人(第1组),100例阻塞性肺病(第2组)和100例限制性肺病(第3组),这些患者在1年内连续进行了两次胸部CT扫描。使用基于阈值的三维自动分割技术测量了CT肺容量,默认范围为–200至–1024 HU。评估受试者内部标准偏差,重复性系数,受试者内部系数变异性和组内相关系数。在任何一组中,两次连续的CT肺容积测量之间均未发现显着差异(p> 0.05)。第1、2和3组的受试者内部标准偏差分别为441.1、387.0和288.6,而重复性系数分别为1222.6、1072.6和800.1。第1、2和3组的受试者内部系数变异分别为0.097、0.083和0.090,而组内相关系数分别为0.818、0.881和0.910。两次CT肺容量测量结果显示,健康个体与阻塞性或限制性肺部疾病患者的一致性非常好。但是,健康个体的可重复性低于肺部疾病的患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号