Obesity and the metabolic syndrome are two pathologies whose prevalence are in a constant increase. Evaluation of the total fat mass but also of the distribution between visceral and subcutaneous adipose tissue are important factors while assessing the pathophysiology of these two pathologies. Computed tomography (CT) and bioimpedance (BIS) are the translational methods the most frequently used in human beings as well as in rodent models in longitudinal studies on adiposity and obesity. Surprisingly, no direct comparison of micro-CT and BIS was reported yet in mice. Therefore, the present study was carried out to evaluate and compare the accuracy and the uncertainty of measurement of micro-CT and BIS in this species.The proportion of fat mass was measured with BIS, micro-CT and direct post-mortem tissue weight, and correlations between the data were established to evaluate the accuracy of the methods but also the uncertainty of BIS and micro-CT.There were significant correlations between weights of fat tissues on scale and proportion of total fat mass determined by BIS or micro-CT (r = 0.81 and 0.86 respectively) but both methods overestimated the total fat mass, especially in the smallest animals; overestimation of fat mass was amplified with BIS compared to micro-CT. In addition BIS and micro-CT were highly correlated (r = 0.94). Test-test reliability showed a greater variability of the BIS with respect to the micro-CT (coefficient of variation = 17.2 vs 5.6% respectively). Hence, as far as subtle differences between groups or changes within one group are awaited, micro-CT may appear as the most reliable method for determination of fat mass in mice. Micro-CT, unlike BIS, will also allow to qualitatively and quantitatively differentiate between subcutaneous and visceral adipose tissues, which is of major importance in studies on adiposity and its complications.
机译:肥胖和代谢综合症是两种发病率不断增加的病理。在评估这两种病理的病理生理学时,评估总脂肪量以及内脏与皮下脂肪组织之间的分布是重要因素。计算机断层扫描(CT)和生物阻抗(BIS)是人类以及肥胖和肥胖症纵向研究中的啮齿动物模型中最常用的翻译方法。出人意料的是,尚未在小鼠中报道过micro-CT和BIS的直接比较。因此,本研究旨在评估和比较该物种中Micro-CT和BIS测量的准确性和不确定性。通过BIS,micro-CT和直接验尸组织重量来测量脂肪量的比例,建立数据之间的相关性以评估方法的准确性,以及BIS和micro-CT的不确定性.BIS或micro-CT确定的脂肪组织重量与规模和总脂肪量比例之间存在显着相关性( r分别为0.81和0.86),但两种方法都高估了总脂肪量,尤其是在最小的动物中;与微型CT相比,BIS放大了对脂肪量的高估。此外,BIS和micro-CT高度相关(r = 0.94)。测试-测试的可靠性表明,相对于微型CT,BIS的可变性更大(变化系数分别为17.2和5.6%)。因此,只要等待组之间的细微差异或一组内的变化,micro-CT可能是确定小鼠脂肪量的最可靠方法。与BIS不同,Micro-CT还可以定性和定量地区分皮下和内脏脂肪组织,这在肥胖及其并发症的研究中具有重要意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号