首页> 美国卫生研究院文献>other >The effect of osseodensification and different thread designs on the dental implant primary stability
【2h】

The effect of osseodensification and different thread designs on the dental implant primary stability

机译:骨密化和不同螺纹设计对牙种植体初级稳定性的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background >: It is difficult to achieve good primary stability of dental implants in soft bone, such as that in the posterior maxillae. Osseodensification (OD) burs, working in a non-subtractive fashion, condense the implant osteotomy bone in lateral direction and increase in the bone implant contact. Also, dental implants with deeper threads, and decreased thread pitch can increase initial bone implant anchorage. >Methods: This study utilized 48 custom-made machined surface dental implants that were 13 mm long, with a major diameter of 4.5 mm and a minor diameter of 3.5 mm, a thread pitch of 1 mm, a thread depth of 0.5 mm, and a 4 mm long cutting flute at the apex.  The implants were divided into 4 groups, each group was made of 12 implants with a different thread design; V-shaped, trapezoid, buttress, and reverse buttress. The implants were inserted in 4-mm thick cancellous bone slices obtained from the head of Cow femur bone. The ostoetomies were prepared by conventional drilling and by OD drilling. Each inserted implant was then tested for primary stability using the Periotest. The Periotest values (PTVs) for the implant stability were tabulated and analyzed using a chi square test at significance level p< 0.05. >Results >: The results of this this study revealed no statistically significant difference between the Periotest readings for the implants in each category placed in either the OD or the regular osteotomies. However, it has been found that the implants placed in regular drilling ostoetomies had a significantly better primary stability than the implants placed in OD osteotomies. >Conclusions >: It was concluded that OD is not necessary in situations where there is bone of good quality and quantity.
机译:>背景 >:很难在软骨(例如上颌后骨)中获得良好的牙齿植入物初步稳定性。骨致密化(OD)毛刺以非减法方式工作,在横向方向上凝结了植入物截骨,并增加了骨植入物的接触。同样,具有更深螺纹的牙植入物和减小的螺距会增加初始骨植入物的锚固。 >方法:这项研究使用了48个定制的机加工表面牙科植入物,它们长13毫米,长径4.5毫米,短径3.5毫米,螺距为1毫米,螺纹深度为0.5毫米,在顶端有4毫米长的切槽。植入物分为4组,每组由12种不同螺纹设计的植入物制成。 V形,梯形,支撑和反向支撑。将植入物插入从母牛股骨骨头获得的4毫米厚的松质骨切片中。造口术是通过常规钻孔和OD钻孔制备的。然后使用Periotest测试每个插入的植入物的主要稳定性。将植入物稳定性的Periotest值(PTV)制成表格,并在显着性水平p <0.05下使用卡方检验进行分析。 >结果 >:该研究的结果表明,放置在OD或常规截骨术中每种类别的植入物的Periotest读数之间在统计学上无显着差异。但是,已经发现,与常规的OD截骨术相比,常规钻孔截骨术的植入物具有更好的初步稳定性。 >结论 >:结论是,在有质量和数量良好的骨骼的情况下,OD是不必要的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号